Effects of implantable cardioverter defibrillator implantation and shock application on biochemical markers of myocardial damage.

نویسندگان

  • T Schlüter
  • H Baum
  • A Plewan
  • D Neumeier
چکیده

BACKGROUND Implantable cardioverter defibrillator (ICD) implantation is a common approach in patients at high risk of sudden cardiac death. To check for normal function, it is necessary to test the ICD. For this purpose, repetitive induction and termination of ventricular fibrillation by direct current shocks is required. This may lead to minor myocardial damage. Cardiac troponin T (cTnT) and I (cTnI) are specific markers for the detection of myocardial injury. Because these proteins usually are undetectable in healthy individuals, they are excellent markers for detecting minimal myocardial damage. The objective of this study was to evaluate the effect of defibrillation of induced ventricular fibrillation on markers of myocardial damage. METHODS This study included 14 patients who underwent ICD implantation and intraoperative testing. We measured cTnT, cTnI, creatine kinase MB (CK-MB) mass, CK activity, and myoglobin before and at definite times after intraoperative shock application. RESULTS Depending on the effectiveness of shocks and the energy applied, the cardiac-specific markers cTnT and cTnI, as well as CK-MB mass, showed a significant increase compared with the baseline value before testing and peaked for the most part 4 h after shock application. In contrast, the increases in CK activity and myoglobin were predominantly detectable in patients who received additional external shocks. CONCLUSIONS ICD implantation and testing leads to a short release of cardiac markers into the circulation. This release seems to be of cytoplasmic origin and depends on the number and effectiveness of the shocks applied.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Implantable cardioverter-defibrillator in a patient with dextrocardia situs inversus

Background: Dextrocardia is a congenital anomaly, which may have coexistent coronary artery disease (CAD), arrhythmias and conventional indications for device therapy. However, the implantation of transvenous leads can be technically challenging and the approach needs to be tailored to the patient's individual anatomy. Case presentation: A 54-year-old male with dextrocardia situs inversus and i...

متن کامل

The effect of education based on Orem’s self-care model on emotional reactions in patients with Implantable Cardioverter Defibrillator (ICD)

Abstract Aim. The purpose of this study was to examine the effect of education based on Orem’s self-care model on emotional reactions in people with Implantable Cardioverter Defibrillator (ICD). Background. ICD shock is unpredictable and associated with physical pain. After receiving shock, some patients find serious psychological problems such as anxiety, depression and stress. According to Or...

متن کامل

Decreased Defibrillation Threshold and Minimized Myocardial Damage With Left Axilla Implantable Cardioverter Defibrillator Implantation.

BACKGROUND To reduce myocardial damage caused by implantable cardioverter defibrillator (ICD) shock, the left axilla was studied as an alternative pulse generator implantation site, and compared with the traditional implantation site, the left anterior chest. METHODSANDRESULTS Computer simulation was used to study the defibrillation conduction pattern and estimate the simulated defibrillation...

متن کامل

THE EFFECT OF NURSE-PEER-LED SUPPORT INTERVENTION ON QUALITY OF LIFE IN PATIENTS WITH AN IMPLANTABLE CARDIOVERTER-DEFIBRILLATOR: A RANDOMIZED CLINICAL TRIAL

Background & Aims: Nowadays, the quality of life and how coping and treatment of patients with an implantable cardiac defibrillator has led to concern and attempts to reduce or eliminate the problems of these patients in the people who provide health care services. This study aimed to determine the effect of nurse-peer-led support intervention on quality of life in patients with an implantable ...

متن کامل

Is correction for metallic artefacts mandatory in cardiac SPECT/CT imaging in the presence of pacemaker and implantable cardioverter defibrillator leads?

Introduction: Metallic artifacts due to pacemaker/ implantable cardioverter defibrillator (ICD) leads in CT images can produce artifactual uptake in cardiac SPECT/CT images. The aim of this study was to determine the influence of the metallic artifacts due to pacemaker and ICD leads on myocardial SPECT/CT imaging. Methods: The study included 9 patients wh...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Clinical chemistry

دوره 47 3  شماره 

صفحات  -

تاریخ انتشار 2001