Collagen fiber orientation around machined titanium and zirconia dental implant necks: an animal study.
نویسندگان
چکیده
PURPOSE To evaluate in vivo collagen fiber behavior around two different dental implant necks placed in the mandibular bone of adult pigs. MATERIALS AND METHODS Scanning electron microscopic (SEM) and profilometric analyses were performed on both types of implant necks to evaluate the different surface morphology. Ten dental implants with machined titanium necks and 20 implants with zirconia necks were inserted into the mandibles of five adult pigs. Three months later, the animals were sacrificed; samples from the peri-implant mucosa were obtained and prepared for histologic analysis. Evaluation of collagen fiber orientation in the connective tissue surrounding the implant necks was performed by polarized light microscopy. Inflammation in the peri-implant soft tissues was also measured via the Gingival Index. RESULTS Postoperative healing was uneventful; all implants, except for one of each type, were osseointegrated after 3 months. SEM and profilometric analyses confirmed that zirconia necks showed Ra, Rq, and Rz values that were lower than those seen around the titanium necks. Histologic observation indicated that collagen fiber orientation was similar for both types of implants. The majority of fibers showed a parallel or parallel-oblique orientation to the implant surface for all samples. Implants that were not osseointegrated, as determined by clinical evaluation, showed inflammatory infiltrate, whereas healthy connective tissue was found around all the other implant necks. CONCLUSIONS Collagen fiber orientation was similar, regardless of implant material, demonstrating a predominantly parallel or parallel-oblique pattern. Moreover, zirconia, which is used as a transgingival collar on some implants, showed connective tissue adhesion that was similar to that seen on the machined titanium surface, but demonstrated limited plaque formation and may provide better esthetics.
منابع مشابه
Effect of Zirconia Dental Implant Surfaces on Bone Integration: A Systematic Review and Meta-Analysis
Background. The information available about osseointegration and the bone to implant interaction of zirconia implants with various surface modifications is still far from sufficient. Objective. The purpose of this systematic review and meta-analysis was to evaluate and compare zirconia dental implants with different surface topographies, with a focus on bone to implant contact and removal torqu...
متن کاملEffect of Abutment Angulation and Material on Stress and Strain Distributions in Premaxillary Bone: A Three-Dimensional Finite Element Analysis
Background and Aim: Dental implants with angled abutments are often inserted in the anterior maxillary region due to the status of the residual ridge and aesthetic considerations. The purpose of this study was to assess stress and strain distributions in the premaxillary bone around dental implants by means of finite element analysis (FEA). Materials and Methods: Four three-dimensional (3D) fi...
متن کاملEvaluation of the Effect of Zirconia and Titanium Abutments on Microleakage of Implant-Abutment Interface Under Oblique Cyclic Loading In Vitro
Background and Aim: Oral bacteria can proliferate in the implant-abutment interface (IAI) and cause inflammation in the peri-implant tissues and adjacent bone. This study aimed to assess the effect of zirconia and titanium abutments on the microleakage of the IAI under oblique cyclic loading conditions. Materials and Methods: In this in-vitro study, 12 implant-abutment assemblies with zirconia...
متن کاملCementum formation around a titanium implant: a case report.
Animal studies have shown that a periodontal ligament may be produced around a titanium implant when it is in contact with fractured and retained roots. Formation of cementum and attachment connective tissue around titanium implants confirms that cementum progenitor cells are located in the periodontal ligament, since cementum and periodontal ligament are present at the implant-root interface, ...
متن کاملOsseointegration of Zirconia (Y-TZP) Dental Implants: A Histologic, Histomorphometric and Removal Torque Study in the Hip of Sheep
Objectives: The purpose of the present study was to demonstrate the biocompatibility and rigid osseointegration of a zirconia (Y-TZP) dental implant with acid-etched surface. Materials and methods: Eight zirconia (Y-TZP) implants (CeraRoot, Barcelona) were inserted in the hip of an adult sheep. The animal was sacrificed after 2 months. Four implants were used for histology and histomorphometric...