Pitfalls in the American Monitor kit methods for determination of total and "direct" bilirubin.

نویسندگان

  • B T Doumas
  • B W Perry
  • B Jendrzejczak
  • V Katona
چکیده

We evaluated the American Monitor Corporation kit for total and direct-reacting bilirubin and found that it suffers serious deficiencies, which lead to inaccurate and imprecise results. The main problem with the total-bilirubin procedure is that the short reaction time (2 min) is inadequate for completion of the reaction. The poor precision of the direct-bilirubin method is due to the short reaction time and the inability of the "stabilizer" (hydroxylamine sulfate) to completely destroy the diazo reagent. Depending on when Fehling's reagent is added, the reaction time may vary from 2 min to 7 min. Values for direct bilirubin at 7 min exceed those obtained at 2 min by 17 to 29%. The short reaction time makes color development temperature dependent, an additional source of imprecision. The suboptimal concentration of the diazo reagent results in underestimation of direct-reacting bilirubin. We recommend changes that improve both precision and accuracy of the kit procedures.

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Quantitative Assessment of Analytical Phase Quality of Clinical Biochemistry Parameters Using Sigma Metrics

Background and Aims: Six sigma is the latest version of total quality management. It is quantitative goal for process performance. With increasing demands for improved accuracy and reliability of the results, Six Sigma is gaining increased visibility in the clinical laboratory process outcomes. The aim of study was to evaluate the quality of analytical phase performance in a clinical biochemist...

متن کامل

Does routine repeat testing of critical laboratory values improve their accuracy?

  Background: Routine repeat testing of critical laboratory values is very common these days to increase their accuracy and to avoid reporting false or infeasible results. We figure that repeat testing of critical laboratory values has any benefits or not.   Methods : We examined 2233 repeated critical laboratory values in 13 different hematology and chemistry tests including: hemoglobin, white...

متن کامل

آیا بیلی روبین می‌تواند شاخصی برای پیشگویی بیماری شریان کرونر باشد؟

Background and Aim: Oxidative interactions such as the formation of oxygen, peroxy radicals and LDL-cholesterol oxidation are involved in the development of atherosclerosis process This study aims to examine the relationship between serum bilirubin levels and the incidence of coronary artery disease. Materials and Methods: Eighty-five patients and ninety-two healthy volunteers were enrolled i...

متن کامل

Evaluation of Urinary Tract Infection in Newborns with Jaundice in South of Iran

Background: Neonatal jaundice is clinically presented in 60% of full-term newborns. About 8% of newborns with jaundice have urinary tract infection (UTI) without any other clinical signs in favor of UTI. In present study we evaluated clinical and paraclinical data that help to rapid and early diagnosis of UTI in apparently healthy newborns with jaundice. Methods: From February to August 2006, 5...

متن کامل

Positive interference in Radioimmunoassay determination of serum total T3

Introduction: Determination of thyrotropin, total and free thyroxine and triiodothyronine are widely used as diagnostic methods for thyroid function evaluation. There have been numerous reports of interferences in thyroid hormone immunoassays. Herein, a prominent positive interference is reported for a radioimmunoassay kit of total triiodothyronine. Materials and Methods: In this study, a total...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:
  • Clinical chemistry

دوره 28 11  شماره 

صفحات  -

تاریخ انتشار 1982