Diagnostic performance of the platelet function analyzer (PFA-100) for the detection of disorders of primary haemostasis in patients with a bleeding history-a systematic review and meta-analysis.
نویسندگان
چکیده
The Platelet Function Analyzer (PFA-100) is increasingly being used in the workup of patients with a bleeding diathesis. A profound knowledge of the possible diagnostic performance of this test is essential in order to make sound clinical decisions based on its results. It was the aim of this study to systematically review the published literature and provide valid estimates of the diagnostic performance of the PFA-100 for detecting disorders of primary haemostasis in newly presenting patients with a bleeding diathesis. A comprehensive literature search was performed for studies published between January 1994 and February 2006. Studies were eligible for the systematic review if they provided data supposed to be applicable to the determination of the diagnostic performance of the PFA-100. Furthermore, they were included in a meta-analysis if study reporting allowed calculation of sensitivity and specificity and if study quality ensured minimized biases of these estimates for the described clinical setting. Pooled weighted sensitivity, specificity and diagnostic odds ratio were calculated applying random effects modelling and constructing summary operator characteristic curves. This was done separately for the available test modifications using either collagen/epinephrine (PFA-EPI) or collagen/adenosine-diphosphate (PFA-ADP) for platelet activation. Thirty-six articles were included in the systematic review. Six studies met our eligibility criteria for a meta-analysis. The major reason for exclusion from the meta-analysis was a case-control design. A total of 1486 and 1259 patients were included in the meta-analysis of the diagnostic performance of the PFA-EPI and PFA-ADP, respectively. Pooled weighted sensitivity and specificity of the PFA-EPI/PFA-ADP in detecting a disorder of primary haemostasis were: 82.5/66.9% (95%-confidence interval (95%-CI): 76.0-88.9%/57.9-75.9%), and 88.7/85.5% (95%-CI: 84.3-93.1%/82.0-89.1%). 83/75% of patients with a positive PFA-EPI/PFA-ADP result do have a disorder of primary haemostasis whereas 88/79% with a negative PFA-EPI/PFA-ADP result do not. The PFA-EPI appeared to have a higher sensitivity and better predictive values than the PFA-ADP in detecting disorders of primary haemostasis, although a rigorous gold standard definition for a disorder of primary haemostasis, particularly for platelet disorders, was not applied in most studies. The majority of the studies lacked important requirements for quality and reporting, precluding a more precise and definitive characterization of the clinical utility of the PFA-100. This emphasizes the need for an evidence-based critical appraisal of diagnostic studies in haemostasis research in order to promote the conducting of studies that produce clinically relevant results.
منابع مشابه
Platelet-To-Lymphocyte Ratio as a Predictor of No-Reflow after Primary Percutaneous Coronary Intervention in Patients with ST Elevation Myocardial Infarction: A Systematic Review and Meta-Analysis
Introduction: No-reflow increases the complications and mortality rate of primary percutaneous coronary intervention (PCI). Therefore, it is important to identify patients at a higher risk of developing no-reflow. This study aimed to systematically review the prognostic value of the platelet-to-lymphocyte ratio (PLR) to predict no-reflow. Materials and Methods:</s...
متن کاملPlatelet function analyzer (PFA)-100 closure time in the evaluation of platelet disorders and platelet function: a rebuttal.
BACKGROUND Closure time (CT), measured by platelet function analyzer (PFA-100) device, is now available to the clinical laboratory as a possible alternative or supplement to the bleeding time test. AIM On behalf of the Platelet Physiology Subcommittee of the Scientific and Standardization Committee of the International Society on Thrombosis and Haemostasis (ISTH-SSC), a working Group was form...
متن کاملA Systematic Review and Meta-Analysis of the Safety and Effectiveness of Tenecteplase Versus Alteplase in Treatment of Patients with ST-Elevation Myocardial Infarction
thrombolytic therapy, an appropriate treatment option , if primary angioplasty is not available for the treatment of Acute Myocardial Infarction patients in the early hours after the onset of the symptoms. The aim of this study was to evaluate the safety and effectiveness of the tenecteplase drug vs alteplase in the treatment of STEMI patients. We searched the PubMed, cochrane library, Web Of ...
متن کاملEvaluation of a Platelet Function Analyser (PFA-100) in patients with a bleeding tendency.
OBJECTIVE To investigate pre-analytical variables and the diagnostic performance of the platelet function analyser (PFA-100), a new device to test primary haemostasis in vitro by simulating platelet adhesion and aggregation under high shear stress. METHODS Venous whole citrated blood is aspirated through a capillary towards an aperture of a collagen coated membrane containing either adenosine...
متن کاملValue of Plasma/Serum Neutrophil Gelatinase-Associated Lipocalin in Detection of Pediatric Acute Kidney Injury; a Systematic Review and Meta-Analysis
Background: Major attention has been drawn to the prognostic value of plasma/serum neutrophil gelatinase-associated lipocalin (NGAL) in detection of acute kidney injury (AKI) in children, but still no consensus has been reached. Accordingly, the present study aimed to assess the diagnostic value of this biomarker in detection of acute kidney injury in children through a systematic review and me...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
عنوان ژورنال:
- Platelets
دوره 18 4 شماره
صفحات -
تاریخ انتشار 2007