Coherence-gated Doppler: a fiber sensor for precise localization of blood flow
نویسندگان
چکیده
Miniature optical sensors that can detect blood vessels in front of advancing instruments will significantly benefit many interventional procedures. Towards this end, we developed a thin and flexible coherence-gated Doppler (CGD) fiber probe (O.D. = 0.125 mm) that can be integrated with minimally-invasive tools to provide real-time audio feedback of blood flow at precise locations in front of the probe. Coherence-gated Doppler (CGD) is a hybrid technology with features of laser Doppler flowmetry (LDF) and Doppler optical coherence tomography (DOCT). Because of its confocal optical design and coherence-gating capabilities, CGD provides higher spatial resolution than LDF. And compared to DOCT imaging systems, CGD is simpler and less costly to produce. In vivo studies of rat femoral vessels using CGD demonstrate its ability to distinguish between artery, vein and bulk movement of the surrounding soft tissue. Finally, by placing the CGD probe inside a 30-gauge needle and advancing it into the brain of an anesthetized sheep, we demonstrate that it is capable of detecting vessels in front of advancing probes during simulated stereotactic neurosurgical procedures. Using simultaneous ultrasound (US) monitoring from the surface of the brain we show that CGD can detect at-risk blood vessels up to 3 mm in front of the advancing probe. The improved spatial resolution afforded by coherence gating combined with the simplicity, minute size and robustness of the CGD probe suggest it may benefit many minimally invasive procedures and enable it to be embedded into a variety of surgical instruments.
منابع مشابه
Cardiac-Gated En Face Doppler Measurement of Retinal Blood Flow Using Swept-Source Optical Coherence Tomography at 100,000 Axial Scans per Second.
PURPOSE To develop and demonstrate a cardiac gating method for repeatable in vivo measurement of total retinal blood flow (TRBF) in humans using en face Doppler optical coherence tomography (OCT) at commercially available imaging speeds. METHODS A prototype swept-source OCT system operating at 100-kHz axial scan rate was developed and interfaced with a pulse oximeter. Using the plethysmogram ...
متن کاملSelf-referenced Doppler optical coherence tomography.
Doppler optical coherence tomography (DOCT) allows simultaneous micrometer-scale resolution cross-sectional imaging of tissue structure and blood flow. We demonstrate a fiber-optic polarization-diversity-based differential phase contrast DOCT system as a method to perform self-referenced velocimetry in highly scattering media. Using this strategy, we reduced common-mode interferometer noise to ...
متن کاملHigh speed, wide velocity dynamic range Doppler optical coherence tomography (Part III): in vivo endoscopic imaging of blood flow in the rat and human gastrointestinal tracts.
We previously described a fiber based Doppler optical coherence tomography system [1] capable of imaging embryo cardiac blood flow at 4~16 frames per second with wide velocity dynamic range [2]. Coupling this system to a linear scanning fiber optical catheter design that minimizes friction and vibrations, we report here the initial results of in vivo endoscopic Doppler optical coherence tomogra...
متن کاملModern Diagnostic Techniques for the Assessment of Ocular Blood Flow in Myopia: Current State of Knowledge
Myopia is the most common refractive error and the subject of interest of various studies assessing ocular blood flow. Increasing refractive error and axial elongation of the eye result in the stretching and thinning of the scleral, choroid, and retinal tissues and the decrease in retinal vessel diameter, disturbing ocular blood flow. Local and systemic factors known to change ocular blood flow...
متن کاملInterstitial Doppler optical coherence tomography.
Doppler optical coherence tomography (OCT) can image tissue structure and blood flow at micrometer-scale resolution but has limited imaging depth. We report a novel, linear-scanning, needle-based Doppler OCT system using angle-polished gradient-index or ball-lensed fibers. A prototype system with a 19-guage (diameter of approximately 0.9 mm) echogenic needle is constructed and demonstrates in v...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
عنوان ژورنال:
دوره 4 شماره
صفحات -
تاریخ انتشار 2013