Nonrigid autofocus motion correction for coronary MR angiography with a 3D cones trajectory.

نویسندگان

  • R Reeve Ingle
  • Holden H Wu
  • Nii Okai Addy
  • Joseph Y Cheng
  • Phillip C Yang
  • Bob S Hu
  • Dwight G Nishimura
چکیده

PURPOSE To implement a nonrigid autofocus motion correction technique to improve respiratory motion correction of free-breathing whole-heart coronary magnetic resonance angiography acquisitions using an image-navigated 3D cones sequence. METHODS 2D image navigators acquired every heartbeat are used to measure superior-inferior, anterior-posterior, and right-left translation of the heart during a free-breathing coronary magnetic resonance angiography scan using a 3D cones readout trajectory. Various tidal respiratory motion patterns are modeled by independently scaling the three measured displacement trajectories. These scaled motion trajectories are used for 3D translational compensation of the acquired data, and a bank of motion-compensated images is reconstructed. From this bank, a gradient entropy focusing metric is used to generate a nonrigid motion-corrected image on a pixel-by-pixel basis. The performance of the autofocus motion correction technique is compared with rigid-body translational correction and no correction in phantom, volunteer, and patient studies. RESULTS Nonrigid autofocus motion correction yields improved image quality compared to rigid-body-corrected images and uncorrected images. Quantitative vessel sharpness measurements indicate superiority of the proposed technique in 14 out of 15 coronary segments from three patient and two volunteer studies. CONCLUSION The proposed technique corrects nonrigid motion artifacts in free-breathing 3D cones acquisitions, improving image quality compared to rigid-body motion correction.

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Accelerated isotropic resolution 3D image-based navigators for coronary MR angiography

PURPOSE To develop a method for acquiring whole-heart 3D image-based navigators (iNAVs) with isotropic resolution for tracking and correction of localized motion in coronary magnetic resonance angiography (CMRA). METHODS To monitor motion in all regions of the heart during a free-breathing scan, a variable-density cones trajectory was designed to collect a 3D iNAV every heartbeat in 176 ms wi...

متن کامل

Technical note: Accelerated nonrigid motion‐compensated isotropic 3D coronary MR angiography

PURPOSE To develop an accelerated and nonrigid motion-compensated technique for efficient isotropic 3D whole-heart coronary magnetic resonance angiography (CMRA) with Cartesian acquisition. METHODS Highly efficient whole-heart 3D CMRA was achieved by combining image reconstruction from undersampled data using compressed sensing (CS) with a nonrigid motion compensation framework. Undersampled ...

متن کامل

Multi-Phase Coronary MR Angiography Using a 3D Cones Trajectory

Introduction: Non-invasive visualization of the coronary arteries in vivo is one of the most important goals in cardiovascular imaging. Compared to other paradigms for coronary MR angiography (MRA), a 3D whole-heart iso-resolution free-breathing approach simplifies prescription effort, requires less patient cooperation, and supports retrospective reformats at arbitrary planes. However, this tec...

متن کامل

Motion‐corrected simultaneous cardiac positron emission tomography and coronary MR angiography with high acquisition efficiency

PURPOSE Develop a framework for efficient free-breathing simultaneous whole-heart coronary magnetic resonance angiography (CMRA) and cardiac positron emission tomography (PET) on a 3 Tesla PET-MR system. METHODS An acquisition that enables nonrigid motion correction of both CMRA and PET has been developed. The proposed method estimates translational motion from low-resolution 2D MR image navi...

متن کامل

Novel prospective respiratory motion correction approach for free-breathing coronary MR angiography using a patient-adapted affine motion model.

A novel technique is presented which enables the calibration of a 3D affine respiratory motion model to the individual motion pattern of the patient. The concept of multiple navigators and precursory navigators is introduced to address nonlinear properties and hysteresis effects of the model parameters with respect to the conventional diaphragmatic navigator. The optimal combination and weighti...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:
  • Magnetic resonance in medicine

دوره 72 2  شماره 

صفحات  -

تاریخ انتشار 2014