Evaluation of Radiation Doses and Dose Conversion Coefficients for Pediatric Cardiac Catheterization Procedures

نویسندگان

  • Abdalla N. Al-Haj
  • Aida M. Lobriguito
  • Walid Rafeh
چکیده

Pediatric cardiac catheterization covers both diagnostic and therapeutic procedures that range from simple to complex and can subject pediatric patients to varying radiation doses. There is limited information on radiation doses delivered by pediatric cardiac catheterization procedures and there is no recommended reference dose levels established yet. The study aims to determine the variation in patient radiation doses in terms of dose area product values and effective doses; determine factors that contribute to high doses to optimize protection; and determine the effective dose conversion coefficient. It is also aimed to provide data to help in the establishment of reference dose levels. A total of 761 pediatric patients belonging to age groups 0, 1, 5 and 10 years who undergo diagnostic and three selected therapeutic procedures at King Faisal Specialist Hospital & Research Centre, Riyadh, Saudi Arabia are included in the study. Therapeutic procedures include COA, PDA and pulmonary procedures. Fluoroscopy and cine radiography are used in all procedures. Patient demography (weight, age, gender and height), radiographic technique factors, fluoroscopy and cine time, frame rate, and dose area product values are taken from patients records. Results show that the kVp varies by ± 1 kVp between procedures and by ± 6 kVp between AP and oblique + lateral projection for all procedures. The mA for lateral and oblique is about 40-70% higher than for AP. Effective doses for each procedure are estimated from the DAP values. The mean DAP and effective dose per procedure are analyzed for correlation with patient equivalent cylindrical diameter, weight, fluoroscopy time and number of frames. Initial results show that age group 0 and 1 year old have the highest mean value for effective dose (11.3 and 13.8 mSv respectively) for pulmonary procedure. Pooling all ages for each procedure, the pulmonary and PDA procedures gave the highest mean values for effective dose (10 and 8.2 mSv respectively) and DAP (1055 and 1048 cGy-cm respectively). An effective dose conversion coefficient of 120 cGy-cm per mSv was obtained when all ages were pooled for all procedures.

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Effective Dose of Radiation in Diagnostic and Interventional Cardiac Angiography among Pediatrics and Adolescents in Hospitals of Shiraz University of Medical Sciences versus Other Radiology Devices

Background: Cardiac catheterization and angiography are diagnostic and therapeutic imaging modalities that produce the highest X-ray radiation, which might impose lifelong risks to patients. This study aimed to evaluate radiation burden among children and adolescents with congenital heart diseases, who underwent cardiac catheterization and angiography. Then the results were compared with other ...

متن کامل

Patient-specific dose and radiation risk estimation in pediatric cardiac catheterization.

BACKGROUND Because of the higher radiosensitivity of infants and children compared with adults, there is a need to evaluate the doses delivered to pediatric patients who undergo interventional cardiac procedures. However, knowledge of the effective dose in pediatric interventional cardiology is very limited. METHODS AND RESULTS For an accurate risk estimation, a patient-specific Monte Carlo s...

متن کامل

Direct measurement of a patient's entrance skin dose during pediatric cardiac catheterization

Children with complex congenital heart diseases often require repeated cardiac catheterization; however, children are more radiosensitive than adults. Therefore, radiation-induced carcinogenesis is an important consideration for children who undergo those procedures. We measured entrance skin doses (ESDs) using radio-photoluminescence dosimeter (RPLD) chips during cardiac catheterization for 15...

متن کامل

Evaluation of Radiation Exposure Pattern and Radiation Absorbed Dose Resulting from Occupational Exposure of Anesthesiologists to Ionizing Radiation

Introduction: Little information is available concerning the radiation exposure of anesthesiologists, and no such data have previously been collected in Iran. This prospective study was performed to determine the amount of radiation exposure of anesthesiologists for the purpose of assessing whether or not dangerous levels of radiation exposures were being reached, and to identify factors that c...

متن کامل

Evaluation of the annual effective dose to Cath Lab staff in the Afshar Hospital, Yazd and suggesting the radiation protection strategies to better management of occupational dose

Introduction Due to the increasing use of angiography procedures and the higher risk of deterministic and stochastic effects for radiation workers of these sections than other radiological procedures, radiation safety is very important in angiography staff. So, this study aimed to obtain the effective dose of angiography staff and compare them with the standard dose limit and finally outline th...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:

دوره   شماره 

صفحات  -

تاریخ انتشار 2008