Concurrent validity of calipers and ultrasound imaging to measure interrecti distance.

نویسندگان

  • Cynthia M Chiarello
  • J Adrienne McAuley
چکیده

STUDY DESIGN Clinical measurement, concurrent validity criterion standard. OBJECTIVE To determine the concurrent validity of digital nylon calipers in comparison to ultrasound imaging (USI) for the measurement of interrecti distance (IRD). BACKGROUND Diastasis rectus abdominis is the abnormal increase in the width of the linea alba, measured as IRD. A diastasis rectus abdominis can compromise mechanical trunk function in both genders. IRD has been accurately measured with USI but requires costly equipment and extensive examiner training. Digital nylon calipers are inexpensive and easy to use, but their use to measure IRD has not been validated. METHODS A sample of convenience of 56 individuals (11 men, 45 women) was measured. A single examiner was assigned to each tool (calipers or USI), and IRD was measured at 2 locations (above and below the umbilicus) under 2 conditions (abdominal muscles at rest and abdominal muscles contracted). All measurements were made during a single session, and examiners were blinded to measurements with the other tool. RESULTS Above the umbilicus, the measurements of IRD with calipers were similar to those made with USI, with intraclass correlation coefficients (model 3,2) of 0.79 with abdominal muscles at rest and 0.71 with abdominal muscles contracted. The absolute mean difference between the caliper and USI measurements of IRD above the umbilicus was 0.03 cm larger with the calipers when the abdominal muscles were at rest and 0.03 cm smaller when the abdominal muscles were contracted. The values of IRD obtained with the caliper and USI techniques were not comparable when obtained below the umbilicus. CONCLUSION The calipers are a valid tool for measuring IRD above the umbilicus in males and females. Measuring IRD with calipers below the umbilicus should not be considered valid, using USI as the criterion standard. This may reflect anatomical variation of the linea alba or a limitation of the calipers to assess IRD at the same depth as USI.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Ultrasound Assessment of the Transverse Carpal Ligament Thickness: A Reliability and Validity Study

Shen, ZL; Gordon, JL; Cheng, J; +Li, ZM +Departments of Biomedical Engineering, Orthopaedic Surgery, and Physical Medicine and Rehabilitation, Cleveland Clinic, Cleveland, OH [email protected] INTRODUCTION: The transverse carpal ligament (TCL) forms the palmar boundary of the carpal tunnel, prevents volar migration of the underlying median nerve and flexor tendons, and plays a critical role in regul...

متن کامل

Rehabilitative ultrasound imaging is a valid measure of trunk muscle size and activation during most isometric sub-maximal contractions: a systematic review.

QUESTIONS Is rehabilitative ultrasound imaging a valid measure of trunk muscle size and activation? Are rehabilitative ultrasound imaging measures sensitive to change? DESIGN Systematic review of studies of criterion-related validity, construct validity, and sensitivity to change. PARTICIPANTS People with low back pain and asymptomatic controls. OUTCOME MEASURE Trunk muscle size and activ...

متن کامل

Design, Evaluation and Prototyping of a New Robotic Mechanism for Ultrasound Imaging

This paper presents a new robotic mechanism for ultrasound imaging. The device is placed on a patient's body by an operator, and an ultrasound expert controls the motions of the device to obtain ultrasound images. The paper focuses on the robotic mechanism that performs ultrasound imaging. The design of the mechanism is based on two approaches to produce center of motion for an ultrasound probe...

متن کامل

Reliability of Ultrasound Imaging of the Trunk Musculature in Athletes with and without Hamstring Injuries

Background: Trunk muscles play an important role in providing both mobility and stability during dynamic tasks in athletes.The purpose of this study was to evaluate the within-day and between-day reliability of ultrasound (US) in measuringabdominal and lumbar multifidus muscle (MF) thickness in athletes with and without hamstring strain injury (HSI).Methods: Fifteen male socce...

متن کامل

Psychometric Evaluation of “Teachers’ Sense of Efficacy Scale” (TSES)

Introduction: Teacher efficacy is the belief of a teacher that he can affect the behavior and academic achievement of learners. Many efforts have been made to measure teacher efficacy but there is no valid and reliable instrument to measure it in Iran. Therefore, this study was performed to translate and psychologically evaluate “teachers’ sense of efficacy scale” (TSES). Methods: This descrip...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • The Journal of orthopaedic and sports physical therapy

دوره 43 7  شماره 

صفحات  -

تاریخ انتشار 2013