Evaluation of real time polymerase chain reaction assays for confirmation of Neisseria gonorrhoeae in clinical samples tested positive in the Roche Cobas Amplicor assay.

نویسندگان

  • S N Tabrizi
  • S Chen
  • M A Cohenford
  • B B Lentrichia
  • E Coffman
  • T Shultz
  • J W Tapsall
  • S M Garland
چکیده

OBJECTIVE Development of a rapid, sensitive, and accurate assay for confirmation of Neisseria gonorrhoeae in clinical samples. METHOD Two real time polymerase chain reaction (PCR) assays, developed on the LightCycler for amplification of the N gonorrhoeae cppB gene, were utilised for confirmation of this bacterial pathogen in samples positive by the Roche Cobas Amplicor assay. Performance characteristics of the two assays were compared with other commercial nucleic acid amplification assays, including the Abbott LCx and Roche 16S rRNA tests. RESULTS All related Neisseria as well as other bacterial species tested negative by both cppB gene based assays, whereas 120 N gonorrhoeae clinical isolates from various geographical regions gave in positive results. Both assays had a sensitivity of one copy per reaction. 122 clinical samples positive and another 50 samples negative for N gonorrhoeae by Roche Cobas Amplicor were selected from a specimen pool of more than 3000 women tested previously. Overall, 73 of 122 (59.8%) samples were confirmed as positive. The two real time assays had sensitivities of 99% and 100% and specificities of 98% and 100%, respectively. The 16S and LCx assays produced similar results to the real time assays, indicating a similar sensitivity to and specificity of both real time assays. CONCLUSION The data from this study highlight the need to confirm N gonorrhoeae positive Cobas Amplicor PCR results as an important part of the testing algorithm of all diagnostic laboratories utilising this assay.

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Evaluation of conventional and real-time PCR assays using two targets for confirmation of results of the COBAS AMPLICOR Chlamydia trachomatis/Neisseria gonorrhoeae test for detection of Neisseria gonorrhoeae in clinical samples.

Two conventional PCR-enzyme immunoassays (PCR-EIAs) and two real-time PCR assays (LightCycler system; Roche Diagnostics) were evaluated as confirmation assays with cppB and 16S rRNA genes as targets. Of 765 male and female genitourinary and nasopharyngeal specimens positive for Neisseria gonorrhoeae in the COBAS AMPLICOR Chlamydia trachomatis/Neisseria gonorrhoeae PCR test (Roche Diagnostics), ...

متن کامل

Neisseria species identification assay for the confirmation of Neisseria gonorrhoeae-positive results of the COBAS Amplicor PCR.

Screening assays for Neisseria gonorrhoeae exhibit low positive predictive values, particularly in low-prevalence populations. A new real-time PCR assay that detects and identifies individual Neisseria spp. using melt curve analysis was compared to two previously published supplementary assays. NsppID, a 16S rRNA real-time PCR/melt curve assay developed to distinguish N. gonorrhoeae from other ...

متن کامل

Specific and sensitive detection of Neisseria gonorrhoeae in clinical specimens by real-time PCR.

Early diagnosis of Neisseria gonorrhoeae infections is important with regard to patients' health and infectivity. We report the development of a specific and sensitive TaqMan assay for the detection of N. gonorrhoeae in clinical samples. The target sequence is a 76-bp fragment of the 5' untranslated region of the opa genes that encode opacity proteins. A panel of 448 well-defined N. gonorrhoeae...

متن کامل

An assessment of the Roche Amplicor Chlamydia trachomatis/Neisseria gonorrhoeae multiplex PCR assay in routine diagnostic use on a variety of specimen types.

The Roche Cobas Amplicor Chlamydia trachomatis/Neisseria gonorrhoeae polymerase chain reaction (PCR) assay can simultaneously detect both C. trachomatis and N. gonorrhoeae, and has been cleared by United States Food and Drug Administration (FDA) for the testing of endocervical and urethral swabs and urine specimens. The Amplicor N. gonorrhoeae PCR target sequence is known to be present in some ...

متن کامل

Detection of Chlamydia trachomatis in genital swabs: comparison of commercial and in house amplification methods with culture.

AIMS To evaluate the sensitivity of the Roche Cobas, Roche Amplicor plate kit, ligase chain reaction (LCR), and an in house polymerase chain reaction (PCR) by titration of purified elementary bodies (EB) and also to test 245 urethral and endocervical specimens for Chlamydia trachomatis by the four assays as well as conventional culture. STUDY DESIGN EB titrations were run in duplicate in each...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:
  • Sexually transmitted infections

دوره 80 1  شماره 

صفحات  -

تاریخ انتشار 2004