Effects of V4c-ICL Implantation on Myopic Patients' Vision-Related Daily Activities
نویسندگان
چکیده
The new type implantable Collamer lens with a central hole (V4c-ICL) is widely used to treat myopia. However, halos occur in some patients after surgery. The aim is to evaluate the effect of V4c-ICL implantation on vision-related daily activities. This retrospective study included 42 patients. Uncorrected visual acuity (UCVA), best corrected visual acuity (BCVA), intraocular pressure (IOP), endothelial cell density (ECD), and vault were recorded and vision-related daily activities were evaluated at 3 months after operation. The average spherical equivalent was -0.12 ± 0.33 D at 3 months after operation. UCVA equal to or better than preoperative BCVA occurred in 98% of eyes. The average BCVA at 3 months after operation was -0.03 ± 0.07 LogMAR, which was significantly better than preoperative BCVA (0.08 ± 0.10 LogMAR) (P = 0.029). Apart from one patient (2.4%) who had difficulty reading computer screens, all patients had satisfactory or very satisfactory results. During the early postoperation, halos occurred in 23 patients (54.8%). However there were no significant differences in the scores of visual functions between patients with and without halos (P > 0.05). Patients were very satisfied with their vision-related daily activities at 3 months after operation. The central hole of V4c-ICL does not affect patients' vision-related daily activities.
منابع مشابه
Implantable collamer lens V4b and V4c for correction of high myopia
PURPOSE To evaluate the visual outcome and intraocular pressure changes after Visian Implantable Collamer Lens (ICL) implantation V4b and V4c (with central hole) for correction of high myopia. METHODS A prospective, consecutive, interventional comparative case series of V4b and V4c ICL implantation was done in high myopic patients who were unsuitable for laser vision. The main outcome measure...
متن کاملComparison of Implantable Collamer Lens Visian ICL V4 and ICL V4c for high myopia
The aim of this study was to investigate the visual quality of the 2 kinds of intraocular lens: Visian implantable collamer lens (ICL) V4 and Visian ICL V4c implantations for high myopia.Twenty cases (20 eyes) with high myopia who received Visian ICL V4 implantation and 18 cases (18 eyes) with high myopia who received Visian ICL V4c implantation in our hospital from April 1, 2014 to November 31...
متن کاملAnterior Chamber Angle Evaluation following Phakic Posterior Chamber Collamer Lens with CentraFLOW and Its Correlation with ICL Vault and Intraocular Pressure
Purpose. To assess intraocular pressure (IOP), lens vaulting, and anterior chamber (AC) angle width, following V4C implantable Collamer lens (ICL) procedure for myopic refractive error. Methods. A prospective case series that enrolled 54 eyes of 27 patients that were evaluated before and after V4C phakic posterior chamber Collamer lens implantation for correction of myopic refractive error. Pre...
متن کاملBuffering zone of implantable Collamer lens sizing in V4c
BACKGROUND The purpose of this study was to identify factors related to the unexpected vault in V4c implantable collamer lens (ICL; STAAR Surgical) implantation. METHODS V4c ICLs were implanted in 43 eyes of 43 patients for the correction of myopia. The implanted V4c ICL sizes were determined individually with our previous V4 ICL sizing nomogram based on the sulcus-to-sulcus diameter (STS), a...
متن کاملComparison of early changes in and factors affecting vault following posterior chamber phakic Implantable Collamer Lens implantation without and with a central hole (ICL V4 and ICL V4c)
BACKGROUND To objectively compare the early changes in vault over time following implantation of an Implantable Collamer Lens without (ICL V4) and with (ICL V4c) a central hole and the respective factors affecting vault change in moderate to high myopia. METHODS This prospective study comprised of 38 eyes of 38 patients implanted with ICL V4 and 39 eyes of 39 patients implanted with ICL V4c i...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
عنوان ژورنال:
دوره 2016 شماره
صفحات -