Feasibility Study for Non-Contact Heartbeat Detection at 2.4 GHz and 60 GHz

نویسندگان

  • Dany OBEID
  • Sawsan SADEK
  • Gheorghe ZAHARIA
  • Ghaïs EL ZEIN
چکیده

Two new schemes for human non-invasive cardiopulmonary activity monitoring are demonstrated using microwave low power and non-contact Doppler sensors. The two systems, using direct conversion architecture and simple design, are demonstrated and tested at a distance of 1 m from the patient. The first one proposes a simple technique for direct measurement of heartbeat signal at 2.4 GHz while the second scheme improves detection sensitivity when operating at 60 GHz.

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Klebsiella pneumonia, a Microorganism that Approves the Non-linear Responses to Antibiotics and Window Theory after Exposure to Wi-Fi 2.4 GHz Electromagnetic Radiofrequency Radiation

Background: Drug resistance is widely believed to be an increasingly serious threat to global public health. We have previously reported that short term exposure of microorganisms to diagnostic ultrasound waves could significantly alter their sensitivity to antibiotics. In our previous studies, Klebsiella pneumoniae showed major differences in the sensitivity to antibiotics in exposed and non-e...

متن کامل

Effect of Microwave Wi-Fi Radiation at Frequency of 2.4 GHz on Epileptic Behavior of Rats

Background: Electromagnetic fields (EMF) with different intensities are widely used at home, offices and public places.Today, there is a growing global concern about the effects of human exposure to EMFs. Epilepsy is one of the most common chronic neurological diseases, affecting 50 million people of all ages worldwide. We aimed to investigate the effect of exposure to Wi-Fi radiation on epilep...

متن کامل

Microwave Doppler Radar for Heart Beat Detection Versus Electrocardiogram: A Validation Approach

This paper provides a validation approach for a microwave Doppler Radar system used for heartbeat detection. The proposed system is tested at 16 GHz with several transmitted power, simultaneously with a pc-based electrocardiogram. Obtained results show accurate detection for the heartbeat signal in terms of heartbeat rate and heart rate variability.

متن کامل

Microwave Doppler Radar for Heart Beat Detection Versus Electrocardiogram

This paper provides a validation approach for a microwave Doppler Radar system used for heartbeat detection. The proposed system is tested at 16 GHz with several transmitted power, simultaneously with a pc-based electrocardiogram. Obtained results show accurate detection for the heartbeat signal in terms of heartbeat rate and heart rate variability.

متن کامل

Design of a Concurrent Dual-Band 1.8–2.4-GHz GaN-HEMT Doherty Power Amplifier

In this paper, the design, implementation, and experimental results of a high-efciency dual-band GaN-HEMT Doherty power amplier (DPA) are presented. An extensive discussion about the design of the passive structures is presented showing different possible topologies of the dual-band DPA. One of the proposed topologies is used to design a dual-band DPA in hybrid technology for the frequency ba...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:

دوره   شماره 

صفحات  -

تاریخ انتشار 2008