Failure to Participate in Turnover Contributes to Manual Reactor Head Vent Isolation Valves Being Left Open during Unit Startup

ثبت نشده
چکیده

Significance: Sep 30, 2002 Identified By: NRC Item Type: FIN Finding UNEXPECTED CHANGES IN UNIT 2 OPERATING PARAMETERS AND DRYER FAILURE DUE TO FLOW INDUCED VIBRATION. The failure to consider the impact of new flow induced vibration failure mechanisms on the Unit 2 steam dryer as part of the extended power uprate analysis resulted in unexpected and unpredictable changes in reactor power, reactor vessel level, reactor pressure, and main steam line flow between June 7 and July 11, 2002. The licensee subsequently determined that the changes in Unit 2 operating parameters were caused by the failure of a Unit 2 steam dryer cover plate. This finding was more than minor because the changes in Unit 2 operating parameters caused by the degraded dryer created conditions which increased the likelihood of a plant transient. However, this finding was of very low risk significance because the changes in plant parameters and the dryer failure did not contribute to the likelihood of a primary or secondary loss of coolant accident initiator, did not contribute to the likelihood of a reactor trip with mitigating equipment not available, and did not increase the likelihood of a fire or an internal or external flood. There were no violations of NRC requirements due to the steam dryer being non-safety related. Inspection Report# : 2002007(pdf)

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

In vitro comparison tests of three LV vent valves.

Many surgical teams employ a sump pump to vent the left ventricle (LV). The problems associated with this technique are related to safety and convenience. If the flow is accidentally reversed in the LV vent line, air embolism accidents and subsequent litigation may be the result. If the cannula is occluded, it is inconvenient to juggle pump speed to prevent the line from collapsing while mainta...

متن کامل

Short-term performance of mitral valve replacement with porcine bioprosthetic valves in dogs.

Porcine bioprosthetic valves cross-linked with glutaraldehyde and polyepoxy compound were newly developed for mitral valve replacement (MVR) in dogs. Five beagle dogs were performed a left thoracotomy and underwent MVR using the porcine bioprosthetic valves during cardiopulmonary bypass (CPB). A vein catheter inserted into right atrium and a vent catheter inserted into the right ventricle to dr...

متن کامل

Efficient drug delivery to the lungs from a continuously operated open-vent nebulizer and low pressure compressor system.

A comparison of aerosol delivery has been made between two open-vent Pari jet nebulizers. Intermittent and continuous delivery were compared for one of the nebulizers. Ten healthy volunteers inhaled 99mTc-labelled diethylenetriamine penta-acetic acid (DTPA) aerosols on three occasions. The Pari LC device was operated both intermittently (by a manual interrupter that generated aerosol only in sy...

متن کامل

Analysis of failure modes and solutions in the process of post open-heart surgery using Fuzzy FMEA and Fuzzy TOPSIS Techniques

Introduction: Intensive Care Unit (ICU) in hospitals is one of the most sensitive and costly units which is really important due to safety and health of patients during their stay in these units. Hence, considering the potential risks in this unit, treatment operations for eliminating or decreasing risks are very important. Among these intensive care units, the most important one is the open-he...

متن کامل

The timing pattern of selected muscles in male children with forward head posture compared to healthy control ones during running

Objective: The aim of this study was to evaluate the muscular activity timing during running in male children with forward head posture compared to healthy control ones. methods: 12 healthy male children with forward head posture (age: 11.7±1.4 years; height: 149.7±6.2 cm; Mass: 38.0±4.7 kg) and 16 healthy male children (age: 11.8±1.5 years; height: 148.2±6.6 cm; mass: 39.6±0.4 kg) were volunt...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره   شماره 

صفحات  -

تاریخ انتشار 2002