A comparison of 3 different endosseous nonsubmerged implants in edentulous mandibles: a clinical report.

نویسندگان

  • A K Røynesdal
  • E Ambjørnsen
  • H R Haanaes
چکیده

The purpose of this prospective clinical study was to investigate the outcome of 3 different types of endosseous, nonsubmerged implants in the anterior part of the mandible. Fourteen older edentulous patients, 10 females and 4 males, were included. All participants received 3 different types of endosseous implants in the anterior mandible: 1 titanium plasma-sprayed cylindric implant (4 mm in diameter), 1 titanium cylindric implant with hydroxyapatite (HA) coating (4 mm in diameter), and 1 standard threaded titanium implant (3.75 mm in diameter). The 3 types of implants were originally designed to be placed in a 2-step surgical procedure. However, at this stage all implants were simultaneously provided with a temporary abutment that penetrated the mucosa. Three months later the temporary abutments were replaced by ball abutments, which were connected to an overdenture. At 12, 24, and 36 months after surgery, marginal bone resorption and Periotest values were recorded. Two patients died within the 2 first postoperative years. Five of 42 implants (11.9%) failed to osseointegrate. After 3 years, marginal bone resorption around titanium plasma-sprayed implants was significantly greater than that seen around both HA-coated and threaded titanium implants. Threaded titanium implants also had significantly better scores for marginal bone resorption than the HA-coated implants. Periotest values for HA-coated cylinders were significantly lower than test values for the other implants after 3 years (P < .05). The conclusion from this investigation is that nonsubmerged implants showed impaired prognoses compared to implants placed according to the 2-stage concept. Marginal bone resorption around titanium plasma-sprayed cylindric implants was clearly increased compared to the 2 other implant systems. Periotest values for HA-coated cylindric implants were superior to titanium plasma-sprayed and pure titanium implant surfaces.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Evaluation of peri-implant tissue in nonsubmerged dental implants: a multicenter retrospective study.

OBJECTIVES The objective of this study was to evaluate the peri-implant's hard and soft tissue response associated with the 1-stage, nonsubmerged, endosseous dental implant. STUDY DESIGN A multicenter retrospective clinical evaluation was performed on 339 nonsubmerged implants placed in 108 patients at 5 clinical centers between January 2003 and December 2007. RESULTS After a mean follow-up...

متن کامل

The extremely resorbed mandible: a comparative prospective study of 2-year results with 3 treatment strategies.

PURPOSE The aim of this prospective clinical study was to compare the clinical and radiographic results of 3 modes of implant treatment in combination with an overdenture in patients with extremely resorbed mandibles. The 3 treatment strategies used were a transmandibular implant, augmentation of the mandible with an autologous bone graft followed by placement of 4 endosseous implants, and the ...

متن کامل

A long-term retrospective analysis of survival rates of implants in the mandible.

PURPOSE To retrospectively analyze the survival rate of endosseous dental implants placed in the edentulous or partially edentulous mandible over a long-term follow-up period of 10 years or more. MATERIALS AND METHODS The charts of patients who underwent mandibular implant placement at a private prosthodontics practice and received follow-up care for 10 years or more were included in this stu...

متن کامل

Mandibular fracture in conjunction with bicortical penetration, using wide-diameter endosseous dental implants.

Prosthodontic rehabilitation of a patient with an atrophic edentulous mandible presents a significant challenge in restoring esthetics and function. The purpose of this clinical report is to describe fracture of an atrophic edentulous mandible opposing maxillary natural dentition in association with endosseous dental implants. The patient received two wide-diameter implants in the anterior mand...

متن کامل

"All-on-Four" immediate-function concept with Brånemark System implants for completely edentulous mandibles: a retrospective clinical study.

BACKGROUND Immediate-function Brånemark System implants (Nobel Biocare AB, Gothenburg, Sweden) have become an accepted alternative for fixed restorations in edentulous mandibles, based on documented high success rates. Continuous development is ongoing to find simple protocols for their use. PURPOSE The purpose of this study was to develop and document a simple, safe, and effective surgical a...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • The International journal of oral & maxillofacial implants

دوره 14 4  شماره 

صفحات  -

تاریخ انتشار 1999