Combined supine and prone myocardial perfusion single-photon emission computed tomography with a cadmium zinc telluride camera for detection of coronary artery disease.

نویسندگان

  • Yoshiko Nishiyama
  • Masao Miyagawa
  • Naoto Kawaguchi
  • Masashi Nakamura
  • Tomoyuki Kido
  • Akira Kurata
  • Teruhito Kido
  • Akiyoshi Ogimoto
  • Jitsuo Higaki
  • Teruhito Mochizuki
چکیده

BACKGROUND Myocardial perfusion SPECT (MPS) traditionally requires the patient to be in the supine position, but diaphragmatic attenuation of the inferior wall reduces test specificity. The aim of this study was to assess the feasibility of combined MPS in the supine and prone positions using a novel cadmium zinc telluride (CZT) camera. METHODS AND RESULTS A total of 276 consecutive patients with suspected/known coronary artery disease (CAD) who underwent single-day (99m)Tc-tetrofosmin or (99m)Tc-sestamibi stress/rest CZT SPECT, were enrolled in the study. Seventy-six underwent coronary angiography. Five-minute scan in the supine (S) position and thereafter in the prone (P) position produced images that were visually interpreted to obtain summed stress (SSS) and rest (SRS) scores. A combined stress score (C-SSS) was calculated by grouping anterior perfusion defects observed during supine imaging with inferior half segments observed during prone imaging. The SSS for the supine, prone, and combined protocols were 9±8, 7±8, and 7±8, respectively (P<0.0001). The SRS were 5±8, 4±7, and 6±7, respectively (P=0.005). The area under the ROC curve for the S-SSS, P-SSS, and C-SSS scores was 0.815 (95% CI: 0.713-0.917), 0.813 (0.711-0.914), and 0.872 (0.783-0.961), respectively. Corresponding sensitivities and specificities for detecting CAD were 87% and 50%, 80% and 77%, and 85% and 82%, respectively. C-SSS had significantly better specificity and accuracy than S-SSS (P<0.05). CONCLUSIONS Combined imaging with a CZT camera is suitable for routine clinical MPS and provides greater diagnostic accuracy than supine imaging alone.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Prediction of Changes in Left Ventricular Ejection Fraction after Off-Pump Coronary Artery Bypass Grafting Surgery by Myocardial Perfusion Single-Photon Emission Computed Tomography

Introduction: Left ventricular ejection fraction (LVEF) is considered to be the single most important prognostic factor in patients with previous myocardial infarction. LVEF is not improved in all patients after coronary artery bypass grafting (CABG). This study aimed to assess the possibility of prediction of LVEF changes after CABG using myocardial perfusion gated signle photon emission compu...

متن کامل

Comparison of CTAC and prone imaging for the detection of coronary artery disease using CZT SPECT

BACKGROUND Cadmium-zinc-telluride (CZT) cameras have improved the evaluation of patients with chest pain. However, inferior/inferolateral attenuation artifacts similar to those seen with conventional Anger cameras persist. We added prone acquisitions and CT attenuation correction (CTAC) to the standard supine image acquisition and analyzed the resulting examinations. METHODS AND RESULTS Seven...

متن کامل

Comparison Between Ultrafast and Standard SPECT in Patients with Coronary Artery Disease: A Pilot Study

Background A novel technology has been developed for ultrafast (UF) singlephoton emission computed tomography (SPECT) myocardial perfusion imaging by employing a pin-hole collimation design and multiple cadmium zinc telluride crystal arrays. The purpose of this study was to compare myocardial perfusion imaging obtained by UF-SPECT with standard (S) SPECT in patients with known or suspected coro...

متن کامل

Comparison between ultrafast and standard single-photon emission CT in patients with coronary artery disease: a pilot study.

BACKGROUND A novel technology has been developed for ultrafast (UF) single-photon emission CT (SPECT) myocardial perfusion imaging by using a pinhole collimation design and multiple cadmium zinc telluride crystal arrays. The purpose of this study was to compare myocardial perfusion imaging obtained by UF-SPECT with standard (S) SPECT in patients with known or suspected coronary artery disease. ...

متن کامل

Phase II Safety and Clinical Comparison With Single-Photon Emission Computed Tomography Myocardial Perfusion Imaging for Detection of Coronary Artery Disease

Objectives This was a phase II trial to assess flurpiridaz F 18 for safety and compare its diagnostic performance for positron emission tomography (PET) myocardial perfusion imaging (MPI) with Tc-99m single-photon emission computed tomography (SPECT) MPI with regard to image quality, interpretative certainty, defect magnitude, and detection of coronary artery disease (CAD) ( 50% stenosis) on in...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Circulation journal : official journal of the Japanese Circulation Society

دوره 78 5  شماره 

صفحات  -

تاریخ انتشار 2014