Investigating the Influence of Flip Angle and k-Space Sampling on Dynamic Contrast-Enhanced MRI Breast Examinations
نویسندگان
چکیده
RATIONALE AND OBJECTIVES To retrospectively investigate the effect of flip angle (FA) and k-space sampling on the performance of dynamic contrast-enhanced (DCE-) magnetic resonance imaging (MRI) breast sequences. MATERIALS AND METHODS Five DCE-MRI breast sequences were evaluated (10°, 14°, and 18° FAs; radial or linear k-space sampling), with 7-10 patients in each group (n = 45). All sequences were compliant with current technical breast screening guidelines. Contrast agent (CA) uptake curves were constructed from the right mammary artery for each examination. Maximum relative enhancement, E(max), and time-to-peak enhancement, T(max), were measured and compared between protocols (analysis of variance and Mann-Whitney). For each sequence, calculated values of maximum relative enhancement, E(calc), were derived from the Bloch equations and compared to E(max). Fat suppression performance (residual bright fat and chemical shift artifact) was rated for each examination and compared between sequences (Fisher exact tests). RESULTS Significant differences were identified between DCE-MRI sequences. E(max) increased significantly at higher FAs and with linear k-space sampling (P < .0001; P = .001). Radial protocols exhibited greater T(max) than linear protocols at FAs of both 14° (P = .025) and 18° (P < .0001), suggesting artificially flattened uptake curves. Good correlation was observed between E(calc) and E(max) (r = 0.86). Fat suppression failure was more pronounced at an FA of 18° (P = .008). CONCLUSIONS This retrospective approach is validated as a tool to compare and optimize breast DCE-MRI sequences. Alterations in FA and k-space sampling result in significant differences in CA uptake curve shape which could potentially affect diagnostic interpretation. These results emphasize the need for careful parameter selection and greater standardization of breast DCE-MRI sequences.
منابع مشابه
Effect of Bias in Contrast Agent Concentration Measurement on Estimated Pharmacokinetic Parameters in Brain Dynamic Contrast-Enhanced Magnetic Resonance Imaging Studies
Introduction: Pharmacokinetic (PK) modeling of dynamic contrast-enhanced magnetic resonance imaging (DCE-MRI) is widely applied in tumor diagnosis and treatment evaluation. Precision analysis of the estimated PK parameters is essential when they are used as a measure for therapy evaluation or treatment planning. In this study, the accuracy of PK parameters in brain DCE...
متن کاملKinetic curves of malignant lesions are not consistent across MR systems: The need for improved standardization of breast DCEMRI acquisitions
Introduction: Standardization of breast MR image acquisition is not widespread at this time. There are several manufacturers of MR systems, with different k-space sampling methods and coils. Furthermore, dynamic imaging protocols differ across institutions as to timing resolution, use of fat suppression, and pulse sequences. Unlike x-ray mammography, there are no universally applied quality ass...
متن کاملAutomatic Prostate Cancer Segmentation Using Kinetic Analysis in Dynamic Contrast-Enhanced MRI
Background: Dynamic contrast enhanced magnetic resonance imaging (DCE-MRI) provides functional information on the microcirculation in tissues by analyzing the enhancement kinetics which can be used as biomarkers for prostate lesions detection and characterization.Objective: The purpose of this study is to investigate spatiotemporal patterns of tumors by extracting semi-quantitative as well as w...
متن کاملEffects of Flip Angle Variations on the Accuracy of Perfusion Parameters in DCE-MRI
Introduction: Dynamic contrast-enhanced (DCE-) MRI has become a valuable tool in the assessment of tumors and in the evaluation of the effects of treatment. Kinetic modeling with two or three (including tumor vascular component vp) compartments is commonly used to measure the parameter K, a first order rate constant that describes tumor perfusion and vascular permeability. In its calculation, t...
متن کاملVariable Flip Angle Steady State Free Precession Imaging for Reduction of SAR
Introduction Steady state free precession (SSFP) imaging is used in widespread applications such as breath-hold MRI examinations of the abdomen and cardiac due to its very high signal-sampling efficiency and good tissue contrast. SSFP imaging at a high static field strength of 3 T and greater often suffers from specific absorption rate (SAR) problems because a high flip angle and short repetiti...