Spectroscopic measurement of the refractive index of ion-implanted diamond.

نویسندگان

  • Alfio Battiato
  • Federico Bosia
  • Simone Ferrari
  • Paolo Olivero
  • Anna Sytchkova
  • Ettore Vittone
چکیده

We present the results of variable-angle spectroscopic ellipsometry and transmittance measurements to determine the variation of the complex refractive index of ion-implanted single-crystal diamond. An increase is found in both real and imaginary parts at increasing damage densities. The index depth variation is determined in the whole wavelength range between 250 and 1690 nm. The dependence from the vacancy density is evaluated, highlighting a deviation from linearity in the high-damage-density regime. A considerable increase (up to 5%) in the real part of the index is observed, attributed to an increase in polarizability, thus offering new microfabrication possibilities for waveguides and other photonic structures in diamond.

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Evidence of light guiding in ion-implanted diamond.

We demonstrate the feasibility of fabricating light-waveguiding microstructures in bulk single-crystal diamond by means of direct ion implantation with a scanning microbeam, resulting in the modulation of the refractive index of the ion-beam damaged crystal. Direct evidence of waveguiding through such buried microchannels is obtained with a phase-shift micro-interferometric method allowing the ...

متن کامل

Far-infrared Spectroscopic Study of Diamond Films

High quality polycrystalline diamond films grown on Si substrates by microwave plasma enhanced chemical vapor deposition were characterized in a far-infrared spectroscopic study. The spectroscopic transmissivity data were used to derive a model for the complex refractive index (n – ik) as a function of wavelength in the 10 to 200 cm-1 frequency regime. Similar transmissivity and reflectivity da...

متن کامل

Measurement and comparison of the temperature-dependence of refractive index of water and Plexiglas phantoms by interferometry method for their use in optical calorimetry

In radiation calorimetry by using laser beams and interferometry setups, variations induced by dose absorption in phantom can be precisely measured. Dose absorption and the induced temperature change result in refractive index variation of the material. In order to be able to measure the low amount of absorbed dose in the phantom, temperature dependence of refractive index of the material must ...

متن کامل

Modeling of measurement error in refractive index determination of fuel cell using neural network and genetic algorithm

Abstract: In this paper, a method for determination of refractive index in membrane of fuel cell on basis of three-longitudinal-mode laser heterodyne interferometer is presented. The optical path difference between the target and reference paths is fixed and phase shift is then calculated in terms of refractive index shift. The measurement accuracy of this system is limited by nonlinearity erro...

متن کامل

Determination of complex dielectric functions of ion implanted and implanted-annealed amorphous silicon by spectroscopic ellipsometry

Measuring with a spectroscopic ellipsometer (SE) in the 1.845 eV photon energy region we determined the complex dielectric function (E = e1 + ieZ> of different kinds of amorphous silicon prepared by self-implantation and thermal relaxation (500 “C, 3 h) . These measurements show that the complex dielectric function (and thus the complex refractive index) of implanted a-Si (i-a-Si) differs from ...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:
  • Optics letters

دوره 37 4  شماره 

صفحات  -

تاریخ انتشار 2012