Comparison of strain parameters in dyssynchronous heart failure between speckle tracking echocardiography vendor systems

نویسندگان

  • Wouter M. van Everdingen
  • Alexander H. Maass
  • Kevin Vernooy
  • Mathias Meine
  • Cornelis P. Allaart
  • Frederik J. De Lange
  • Arco J. Teske
  • Bastiaan Geelhoed
  • Michiel Rienstra
  • Isabelle C. Van Gelder
  • Marc A. Vos
  • Maarten J. Cramer
چکیده

BACKGROUND Although mechanical dyssynchrony parameters derived by speckle tracking echocardiography (STE) may predict response to cardiac resynchronization therapy (CRT), comparability of parameters derived with different STE vendors is unknown. METHODS In the MARC study, echocardiographic images of heart failure patients obtained before CRT implantation were prospectively analysed with vendor specific STE software (GE EchoPac and Philips QLAB) and vendor-independent software (TomTec 2DCPA). Response was defined as change in left ventricular (LV) end-systolic volume between examination before and six-months after CRT implantation. Basic longitudinal strain and mechanical dyssynchrony parameters (septal to lateral wall delay (SL-delay), septal systolic rebound stretch (SRSsept), and systolic stretch index (SSI)) were obtained from either separate septal and lateral walls, or total LV apical four chamber. Septal strain patterns were categorized in three types. The coefficient of variation and intra-class correlation coefficient (ICC) were analysed. Dyssynchrony parameters were associated with CRT response using univariate regression analysis and C-statistics. RESULTS Two-hundred eleven patients were analysed. GE-cohort (n = 123): age 68 years (interquartile range (IQR): 61-73), 67% male, QRS-duration 177 ms (IQR: 160-192), LV ejection fraction: 26 ± 7%. Philips-cohort (n = 88): age 67 years (IQR: 59-74), 60% male, QRS-duration: 179 ms (IQR: 166-193), LV ejection fraction: 27 ± 8. LV derived peak strain was comparable in the GE- (GE: -7.3 ± 3.1%, TomTec: -6.4 ± 2.8%, ICC: 0.723) and Philips-cohort (Philips: -7.7 ± 2.7%, TomTec: -7.7 ± 3.3%, ICC: 0.749). SL-delay showed low ICC values (GE vs. TomTec: 0.078 and Philips vs. TomTec: 0.025). ICC's of SRSsept and SSI were higher but only weak (GE vs. TomTec: SRSsept: 0.470, SSI: 0.467) (Philips vs. QLAB: SRSsept: 0.419, SSI: 0.421). Comparability of septal strain patterns was low (Cohen's kappa, GE vs. TomTec: 0.221 and Philips vs. TomTec: 0.279). Septal strain patterns, SRSsept and SSI were associated with changes in LV end-systolic volume for all vendors. SRSsept and SSI had relative varying C-statistic values (range: 0.530-0.705) and different cut-off values between vendors. CONCLUSIONS Although global longitudinal strain analysis showed fair comparability, assessment of dyssynchrony parameters was vendor specific and not applicable outside the context of the implemented platform. While the standardization taskforce took an important step for global peak strain, further standardization of STE is still warranted.

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Evaluation of strain and strain rate parameters using two-dimensional speckle-tracking echocardiography in patients with coronary artery disease (Research Article)

The study aimed was to measure left ventricular (LV) strain using speckle tracking echocardiography (STE) for assessment of LV function. Eighty-two subjects (mean age 57±9 years) with suspected chest pain underwent two-dimensional (2D)-echocardiography before coronary angiography. Conventional echocardiographic parameters were used for the assessment of LV function. Longitudinal strain and its ...

متن کامل

Comparison of CMR DENSE strain imaging and 2D speckle tracking echocardiography for cardiac resynchronization therapy (CRT) response

Background Considering that nonresponse rates to cardiac resynchronization therapy (CRT) are typically 35-50%, assessment of the cardiac substrate for CRT with cardiac imaging could be very helpful for many patients with heart failure referred for this therapy. We have previously shown that CMR assessment of dyssynchrony using displacement encoding with stimulated echoes (DENSE) is strongly ass...

متن کامل

Normal range of left ventricular 2-dimensional strain: Japanese Ultrasound Speckle Tracking of the Left Ventricle (JUSTICE) study.

BACKGROUND To determine the normal range of left ventricular (LV) 2- dimensional (2-D) strain and vendor-specific differences, a multicenter prospective 2-D strain study endorsed by the Japanese Society of Echocardiography was conducted. METHODS AND RESULTS 2-D speckle tracking analysis was performed on 817 healthy subjects (age range, 0-88 years); the images included 3 LV short axis and 3 ap...

متن کامل

Myocardial strain analysis in patients with Heart Failure with preserved Ejection Fraction using bright blood cine MR images: A comparison with speckle-tracking echocardiography

Background Changes in myocardial strain parameters is of interest in patients with heart failure as an objective measure of disease severity. Speckle-tracking echocardiography (STecho) is the accepted standard of reference for myocardial strain analysis given superior temporal resolution; however, difficult acoustic windows and limited contrast to noise resolution can limit strain analysis. Pre...

متن کامل

Synchronicity of systolic deformation in healthy pediatric and young adult subjects: a two-dimensional strain echocardiography study.

Two-dimensional speckle tracking echocardiography (2DSTE) offers valuable information in the echocardiographic assessment of ventricular myocardial function. It enables the quantification and timing of systolic ventricular myocardial deformation. In addition, 2DSTE can be used to identify mechanical dyssynchrony, which is an important parameter in predicting the response to cardiac resynchroniz...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:

دوره 15  شماره 

صفحات  -

تاریخ انتشار 2017