An equivalent circuit model for onset and offset exercise response

نویسندگان

  • Yi Zhang
  • Azzam Haddad
  • Steven W Su
  • Branko G Celler
  • Aaron J Coutts
  • Rob Duffield
  • Cheyne E Donges
  • Hung T Nguyen
چکیده

BACKGROUND The switching exercise (e.g., Interval Training) has been a commonly used exercise protocol nowadays for the enhancement of exerciser's cardiovascular fitness. The current difficulty for simulating human onset and offset exercise responses regarding the switching exercise is to ensure the continuity of the outputs during onset-offset switching, as well as to accommodate the exercise intensities at both onset and offset of exercise. METHODS Twenty-one untrained healthy subjects performed treadmill trials following both single switching exercise (e.g., single-cycle square wave protocol) and repetitive switching exercise (e.g., interval training protocol). During exercise, heart rate (HR) and oxygen uptake (VO2) were monitored and recorded by a portable gas analyzer (K4b 2, Cosmed). An equivalent single-supply switching resistance-capacitor (RC) circuit model was proposed to accommodate the observed variations of the onset and offset dynamics. The single-cycle square wave protocol was utilized to investigate the respective dynamics at onset and offset of exercise with the aerobic zone of approximate 70%-77% of HR max, and verify the adaption feature for the accommodation of different exercise strengths. The design of the interval training protocol was to verify the transient properties during onset-offset switching. A verification method including Root-mean-square-error (RMSE) and correlation coefficient, was introduced for comparisons between the measured data and model outputs. RESULTS The experimental results from single-cycle square wave exercises clearly confirm that the onset and offset characteristics for both HR and VO2 are distinctly different. Based on the experimental data for both single and repetitive square wave exercise protocols, the proposed model was then presented to simulate the onset and offset exercise responses, which were well correlated indicating good agreement with observations. CONCLUSIONS Compared with existing works, this model can accommodate the different exercise strengths at both onset and offset of exercise, while also depicting human onset and offset exercise responses, and guarantee the continuity of outputs during onset-offset switching. A unique adaption feature by allowing the time constant and steady state gain to re-shift back to their original states, more closely mimics the different exercise strengths during normal daily exercise activities.

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Equivalent Circuit Model for Square Ring Slot Frequency Selective Surface

An equivalent circuit model for predicting the frequency response of a square ring slot frequency selective surface (SRS-FSS) for normal incidence is described. The proposed FSS consists of an array of square patches centered within a wire grid. The presented circuit model is formed by the impedance of the wire grid that is parallel with the impedance of the patch array, also the mutual couplin...

متن کامل

Large Lithium Polymer Battery Modeling for the Simulation of Hybrid Electric Vehicles Using the Equivalent Circuit Method

In the present study, a model of a large Lithium Polymer (Li-Po) battery for use in the simulation of Hybrid Electric Vehicles (HEVs) is developed. To attain this goal, an Equivalent Circuit (EC) consisting of a series resistor and two RC parallel networks is considered. The accuracy and the response time of the model for use in an HEV simulator are studied. The battery parameters identifica...

متن کامل

مقایسه مدل‌های فراکتال و مفهوم عدم تطابق و واهلش، در بررسی رسانایی یونی

  A simple equivalent circuit to explain the electrical response of an ionic conductor is a parallel circuit consisting of an electrical resistance and a capacitor. Impedance semicircle of such a circuit is exactly a semicircle, but the impedance semicircle of experimental data is a depressed one. To explain this deformed shape of semicircle, usually CPE (constant phase element) is used in equi...

متن کامل

Acute and Short-Term Effects of Oral Feeding of Jujube Solution on Blood Platelets and its Morphological Indices in Response to a Circuit Resistance Exercise

The present study investigated the acute and short-term effects of oral feeding of jujube solution on blood platelets and its morphological indices in response to circuit resistance exercise. Fourteen young male volunteer students were randomly divided into the placebo and jujube solution groups. All participants performed one circuit resistance exercise[9stations/nonstop, 30 seconds for each s...

متن کامل

Design of a Single-Layer Circuit Analog Absorber Using Double-Circular-Loop Array via the Equivalent Circuit Model

A broadband Circuit Analogue (CA) absorber using double-circular-loop array is investigated in this paper. A simple equivalent circuit model is presented to accurately analyze this CA absorber. The circuit simulation of the proposed model agrees well with full-wave simulations. Optimization based the equivalent circuit model, is applied to design a single-layer circuit analogue absorber using d...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:

دوره 13  شماره 

صفحات  -

تاریخ انتشار 2014