Evaluation of a new ultrasmall superparamagnetic iron oxide contrast agent Clariscan, (NC100150) for MRI of renal perfusion: experimental study in an animal model.
نویسندگان
چکیده
PURPOSE To determine the diagnostic value of a new ultrasmall superparamagnetic iron oxide Clariscan, (NC100150) for the evaluation of renal perfusion in an animal model using a 3D-FFE-EPI sequence. MATERIALS AND METHODS Four groups of four rabbits each were imaged after bolus injection of NC100150, using a 1.5 T MR system (Gyroscan ACS-NT). T2*w MR images in the coronal plane were acquired over 60 seconds with an echo-shifted 3D-FFE-EPI sequence (TR/TE/alpha = 18/25 msec/8 degrees ). Data were transferred to a workstation and converted into concentration curves. Based on the fitted concentration time curves, parameter maps were calculated pixelwise: bolus arrival time (T0), time-to-peak (TTP), mean transit time (MTT), and relative bolus volume (rBV). Maximum signal decrease was determined with respect to the baseline value. RESULTS Mean MTT increased from 4.2 seconds at a dose of 0.25 mg to 5.9 seconds at 1.0 mg (P < .0001). The maximum signal decrease was observed at 0.75 mg, corresponding to 85% of the baseline value. Transit times of the contrast bolus were accurately calculated for the cortex and the outer medulla, but at the level of the inner medulla no arterial flow profile was identified. No significant difference between the cortex and the outer medulla was found for either T0 or rBV, but medullar TTP and MTT were prolonged with regard to cortical TTP and MTT (6.3 seconds vs. 5.7 seconds, P < .001; 5.7 seconds vs. 4.2 seconds, P < .0001). CONCLUSION The employed intravascular contrast agent is well suited to assess renal perfusion. By the use of a T2*w3D perfusion sequence, cortical and medullar transit times can be quantified and physiologic information on regional perfusion differences can be obtained.
منابع مشابه
Potential positive MRI contrast agent based on PVP-grafted superparamagnetic iron oxide nanoparticles with various repetition times
Objective(s): The present study aimed to evaluate the capability of synthesized and modified superparamagnetic iron oxide nanoparticles (SPIONs) as the positive contrast agent in magnetic resonance imaging (MRI) by investigating the effect of repetition time (TR) on the MRI signal intensity. Materials and Methods: SPIONs were synthesized using the co-precipitation method, and their surfac...
متن کاملSystematic review: Superparamagnetic Iron Oxide nanoparticles as contrast agents in diagnosis of multiple sclerosis
Several MRI contrast agents (CAs) are used in medical diagnosis that gadolinium (Gd3+) is the most widely used as contrast agents. Unfortunately, its toxicity is due to its inefficiency. In this review, we discuss about the ability of SPIONs in MRI and application in Multiple Sclerosis diagnosis. Superparamagnetic iron oxide nanoparticles (SPIONs) such as magnetite nanoparticles are used as goo...
متن کاملSystematic review: Superparamagnetic Iron Oxide nanoparticles as contrast agents in diagnosis of multiple sclerosis
Several MRI contrast agents (CAs) are used in medical diagnosis that gadolinium (Gd3+) is the most widely used as contrast agents. Unfortunately, its toxicity is due to its inefficiency. In this review, we discuss about the ability of SPIONs in MRI and application in Multiple Sclerosis diagnosis. Superparamagnetic iron oxide nanoparticles (SPIONs) such as magnetite nanoparticles are used as goo...
متن کاملEmerging applications for ferumoxytol as a contrast agent in MRI.
Ferumoxytol is an ultrasmall superparamagnetic iron oxide (USPIO) agent initially approved by the Food and Drug Administration (FDA) as an iron replacement therapy for patients with anemia due to chronic renal failure. Recently, ferumoxytol has been investigated extensively as an intravenous contrast agent in magnetic resonance imaging (MRI). Since it causes regional T1 and T2 * shortening in v...
متن کاملA New Potential Contrast Agent for Magnetic Resonance Imaging: Iron Oxide-4A Nanocomposite
Background: Magnetic resonance imaging (MRI) contrast agents have an important role to differentiate healthy and diseased tissues. Access and design new contrast agents for the optimal use of MRI are necessary. This study aims to evaluate iron oxide–4A nanocomposite ability to act as a magnetic resonance imaging contrast agent.Materials and Methods: Iron oxide–4A nanocomposite (F4A) was syn...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
عنوان ژورنال:
- Journal of magnetic resonance imaging : JMRI
دوره 16 2 شماره
صفحات -
تاریخ انتشار 2002