Continuous glucose monitoring: real-time algorithms for calibration, filtering, and alarms.
نویسنده
چکیده
Algorithms for real-time use in continuous glucose monitors are reviewed, including calibration, filtering of noisy signals, glucose predictions for hypoglycemic and hyperglycemic alarms, compensation for capillary blood glucose to sensor time lags, and fault detection for sensor degradation and dropouts. A tutorial on Kalman filtering for real-time estimation, prediction, and lag compensation is presented and demonstrated via simulation examples. A limited number of fault detection methods for signal degradation and dropout have been published, making that an important area for future work.
منابع مشابه
Establishing a continuous glucose monitoring program.
Real-time continuous glucose monitoring (RT-CGM) devices provide detailed information on glucose patterns and trends, and alarms that alert the patient to both hyper- and hypoglycemia. This technology can dramatically improve the day-to-day management of patients with diabetes and promises to be a major advance in diabetes care. The safe and effective use of RT-CGM in diabetes management rests ...
متن کاملImpact of retrospective calibration algorithms on hypoglycemia detection in newborn infants using continuous glucose monitoring.
BACKGROUND Neonatal hypoglycemia is common and may cause serious brain injury. Diagnosis is by blood glucose (BG) measurements, often taken several hours apart. Continuous glucose monitoring (CGM) could improve hypoglycemia detection, while reducing the number of BG measurements. Calibration algorithms convert sensor signals into CGM output. Thus, these algorithms directly affect measures used ...
متن کاملImpact of real-time continuous glucose monitoring on children and their families.
Real-time continuous glucose monitoring (CGM) devices have great potential to improve glycemic management in children and adolescents with diabetes and other disorders of glucose regulation. These devices can be used as either adjuncts or replacements for traditional meters because they have additional features such as blood sugar alarms and glucose-trend information. These features allow for d...
متن کاملThe accuracy of a new real-time continuous glucose monitoring algorithm: an analysis.
In this issue of Journal of Diabetes Science and Technology, Keenan and colleagues used archival data from the STAR 1 clinical trial (Medtronic Diabetes) to support the claim that the new Veo calibration algorithm improves the accuracy of continuous glucose monitoring, particularly in the critical hypoglycemic range. Extensive data analyses are presented to support this claim; the results are c...
متن کاملEditorial: symposium on algorithms for continuous glucose monitoring and control.
1 S YSTEMS AND CONTROL THEORY is the basis for algorithms embedded in many of the products (both high and low " tech ") that we use in our daily lives. While consumers appreciate the relative compactness of CD and DVD players and microdrives, for example, and value the manufacturing technology involved in minia-turization, they probably do not think much about the mathematical algorithms that e...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
عنوان ژورنال:
- Journal of diabetes science and technology
دوره 4 2 شماره
صفحات -
تاریخ انتشار 2010