Dynamics of right heart flow in patients after Fontan procedure.
نویسندگان
چکیده
In seven patients who underwent Fontan procedures but in whom no valves were inserted, dynamics of right heart flow were evaluated with the use of a catheter-tipped velocity transducer, pulsed Doppler echocardiography, and angiocardiography. Right atrial (RA) contraction caused a forward flow to the pulmonary artery (PA) and a backward flow to the inferior vena cava (IVC). Backward flow to the superior vena cava (SVC) was minimal. As the right atrium relaxed, a rapid forward flow occurred at the IVC and SVC that filled the atrium and a small amount of pulmonary regurgitant flow was observed. Subsequently, a forward flow was observed at the IVC, SVC, and PA during RA diastole. Angiographically determined RA stroke volume (SV) was less than 40% of the left ventricular (LV) SV in three patients in whom the postoperative increase in atrial "a" wave pressure (delta p) was greater than 8 mm Hg, while it was similar to or greater than LVSV in four patients in whom delta p was 6 mm Hg or less. In all patients LV end-diastolic volume was 107 +/- 27(SD)% of normal but LV ejection fraction was 0.53 +/- 0.07, resulting in the reduced cardiac output (2.8 +/- 0.7 l/min/m2). There was no correlation between the RASV or RA ejection fraction and cardiac output. These data show that the RA contraction causes a forward flow to the PA and that pulmonary regurgitation is not significant after Fontan procedure even when valves are not inserted. Also, the postoperative increase in the RA afterload may depress RA function.(ABSTRACT TRUNCATED AT 250 WORDS)
منابع مشابه
A model to simulate the haemodynamic effects of right heart pulsatile flow after modified Fontan procedure.
The effect of pulsatile pulmonary flow after the modified Fontan procedure was examined in a model that simulated the right heart. An inlet overflow tank (preload), axial pulsatile pump, Wind-Kessel model (afterload), and an outlet overflow tank were connected in series. The standard conditions were flow 2.00 l/min with 12 mm Hg preload pressure, 3.0 Wood units resistance, and an outlet overflo...
متن کاملنتایج جراحی فونتان بدون استفاده از ماشین قلب و ریه در 41 بیمار
Background: The Fontan operation is the definitive operation for palliation of complex congenital heart disease with single –ventricle physiology. The use of the extra cardiac conduit has recently been gaining popularity. The purpose of this study was to compare the outcomes of extra cardiac conduit Fontan procedure (off-pump technique) and that of traditional technique (lateral tunnel techniqu...
متن کاملTHERAPY AND PREVENTION SURGERY Dynamics of right heart flow in patients after Fontan procedure
In seven patients who underwent Fontan procedures but in whom no valves were inserted, dynamics of right heart flow were evaluated with the use of a catheter-tipped velocity transducer, pulsed Doppler echocardiography, and angiocardiography. Right atrial (RA) contraction caused a forward flow to the pulmonary artery (PA) and a backward flow to the inferior vena cava (IVC). Backward flow to the ...
متن کاملEarly diastolic clicks after the Fontan procedure for double inlet left ventricle: anatomical and physiological correlates.
M mode echocardiograms and simultaneous phonocardiograms were recorded in four patients with early diastolic clicks on auscultation. All had double inlet left ventricle and had undergone the Fontan procedure with closure of the right atrioventricular valve orifice by an artificial patch. The phonocardiogram confirmed a high frequency sound occurring 60-90 ms after aortic valve closure and coinc...
متن کاملA quantitative analysis of hemodynamic effects of the right ventricle included in the circulation of the Fontan procedure.
BACKGROUND Right heart hemodynamics were analyzed with a catheter-mounted velocity meter in seven patients after direct atrioventricular anastomosis for Fontan procedure (RV group) and were compared with those obtained in eight patients after direct atriopulmonary anastomosis (RA group). METHODS AND RESULTS In the RV group, cardiac output was 2.7 +/- 0.6 l/min/m2; mean right atrial and pulmon...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
عنوان ژورنال:
- Circulation
دوره 69 2 شماره
صفحات -
تاریخ انتشار 1984