Simplified volumetric flow cytometry allows feasible and accurate determination of CD4 T lymphocytes in immunodeficient patients worldwide.

نویسندگان

  • Uwe Cassens
  • Wolfgang Göhde
  • Gudrun Kuling
  • Arndt Gröning
  • Peter Schlenke
  • Leopold Gustave Lehman
  • Yves Traoré
  • Jean Servais
  • Yvette Henin
  • Doris Reichelt
  • Burkhard Greve
چکیده

The determination of CD4 cells is of crucial clinical importance for patients with AIDS. However, the high costs involved represent limitations for CD4 cell counting in developing countries. In order to provide an affordable technique, we introduced a simplified volumetric counting (SVC) technique without sample manipulations and investigated it in a multicentre study. Blood samples from 434 healthy donors and immunodeficient patients were tested in eight hospital laboratories in Europe, Africa and Asia. CD4 cell counts were compared using in-house flow cytometric methods and the SVC technique. The SVC method was performed on a low-cost flow cytometer (CyFlow SL, Partec, Münster, Germany) after 15 min antibody incubation without pre-analytic manipulations, such as washing or erythrocyte lysing procedures. Linear regression analysis demonstrated a correlation of r=0.942 (Europe), r=0.952 (Africa) and r=0.989 (Asia) between the SVC technique and the in-house methods. Bland Altman plot analysis of all patient data showed a mean bias between the two methods of +26 CD4 cells in favour of the SVC technique (measured range: 6-1905 cells/microl; median CD4 cell count: 388/microl). Three centres used the FACS-count technique (Becton-Dickinson, San José, Calif., USA) as an in-house method dispensing with pre-analytic manipulations. The comparison of SVC and FACS-count method revealed a mean bias of +32 CD4 cells/microl (median CD4 cell count: 349/microl). The accuracy of the SVC was tested on standards with known CD4 cell counts (n=6) and was shown to be 95.2%. The low-cost device and the simplified no-lyse, no-wash test procedure reduces the costs per determination and facilitates the use of flow cytometry in developing countries.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Determination of lymphocytes surface markers in patients with thermal burns and the influence of burn size on mononuclear cell subsets

Background: Thermal burn injuries impair the host defence system. Hence, in the present study, we aimed at investigating the changes in the number and phenotype of peripheral blood lymphocyte populations (T, B, and natural killer cells) and their subpopulations in patients with thermal burns and determining the relationships with different sizes of total body surface area (TBSA).    ...

متن کامل

بررسی ارتباط سلول‌های T CD4+ و سطح سرمی IL-17، IL-11 در ترومبوسیتوپنیک پورپورا

Background: Immune Thrombocytopenic Purpura (ITP) is an acquired autoimmune disorder characterized by a low platelet count because of anti platelet auto-antibodies. ITP patients have auto antibodies against platelet antigens. T CD4+ lymphocytes are effective cells in immune system that has an important role in auto reactive antibody production and class switching. The pathophisiology and mechan...

متن کامل

Quantitative determination of CD4/CD8 molecules by a cell marker ELISA.

Determination of percentages of CD4+ and CD8+ T cells from patients with human immunodeficiency virus infection is usually done by flow cytometric analysis. We compared a cell marker ELISA with flow cytometry for quantitation of CD4 and CD8 molecules on T lymphocytes, and correlated the values both with the number of CD4+ and CD8+ T lymphocytes and with clinical data. Results by cell marker ELI...

متن کامل

Comparative Analysis of CD4+ and CD8+ T Cells in Tumor Tissues, Lymph Nodes and the Peripheral Blood from Patients with Breast Cancer

Background: CD4+ and CD8+ T cells are the main types of lymphocytes in cell-mediated immunity and play a central role in the induction of efficient immune responses against tumors. The frequencies of T cell subtypes in the peripheral blood and tumor tissues, and draining lymph nodes (dLN) can be considered as useful markers for evaluation of the immune system in cancers. Methods: In this study,...

متن کامل

CD4+ T Cells are Exhausted and Show Functional Defects in Chronic Lymphocytic Leukemia

Background: Chronic lymphocytic leukemia (CLL) is the most common adult leukemia in the western world. This health problem is caused due to the accumulation of mature B-lymphocytes in the peripheral blood and bone marrow. In the course of cancer, CD4+ T cells become “exhausted” and characterized with poor effector functions and the expression of multiple inhibitory receptors. Objective: To inve...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Antiviral therapy

دوره 9 3  شماره 

صفحات  -

تاریخ انتشار 2004