Can Dexmedetomidine Improve Arterial Oxygenation and Intrapulmonary Shunt during One-lung Ventilation in Adults Undergoing Thoracic Surgery? A Meta-analysis of Randomized, Placebo-controlled Trials

نویسندگان

  • Su-Qin Huang
  • Jian Zhang
  • Xiong-Xin Zhang
  • Lu Liu
  • Yang Yu
  • Xian-Hui Kang
  • Xiao-Min Wu
  • Sheng-Mei Zhu
چکیده

BACKGROUND One-lung ventilation (OLV) is a common ventilation technology during thoracic surgery that can cause serious clinical problems. We aimed to conduct a meta-analysis to compare oxygenation and intrapulmonary shunt during OLV in adults undergoing thoracic surgery with dexmedetomidine (Dex) versus placebo to assess the influence and safety of using Dex. METHODS Randomized controlled trials comparing lung protection in patients who underwent thoracic surgery with Dex or a placebo were retrieved from PubMed, EMBASE, MEDLINE, Cochrane Library, and China CNKI database. The following information was extracted from the paper: arterial oxygen partial pressure (PaO2), PaO2/inspired oxygen concentration (PaO2/FiO2, oxygenation index [OI]), intrapulmonary shunt (calculated as Qs/Qt), mean arterial pressure (MAP), heart rate (HR), tumor necrosis factor-α (TNF-α), interleukin (IL)-6, superoxide dismutase (SOD), and malondialdehyde (MDA). RESULTS Fourteen randomized controlled trials were included containing a total of 625 patients. Compared with placebo group, Dex significantly increased PaO2/FiO2(standard mean difference [SMD] = 0.98, 95% confidence interval [CI] [0.72, 1.23], P < 0.00001). Besides, Qs/Qt (SMD= -1.22, 95% CI [-2.20, -0.23], P = 0.020), HR (SMD= -0.69, 95% CI [-1.20, 0.17], P = 0.009), MAP (SMD= -0.44, 95% CI [-0.84, 0.04], P = 0.030), the concentrations of TNF-α (SMD = -1.55, 95% CI [-2.16, -0.95], P <0.001), and IL-6 (SMD = -1.53, 95% CI [-2.37, -0.70], P = 0.0003) were decreased in the treated group, when compared to placebo group. No significant difference was found in MDA (SMD = -1.14, 95% CI [-3.48, 1.20], P = 0.340) and SOD (SMD = 0.41, 95% CI [-0.29, 1.10], P = 0.250) between the Dex group and the placebo group. Funnel plots did not detect any significant publication bias. CONCLUSIONS Dex may improve OI and reduce intrapulmonary shunt during OLV in adults undergoing thoracic surgery. However, this conclusion might be weakened by the limited number of pooled studies and patients.

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

The Effect of Dexmedetomidine on Oxygenation and Intrapulmonary Shunt during One Lung Ventilation

Background: The effect of intravenously administered dexmedetomidine on oxygenation during one-lung ventilation has not been studied. The hypothesis of this prospective, randomized study was that dexmedetomidine would be associated with an improvement in oxygenation during onelung ventilation. The secondary outcome was the change in the intrapulmonary shunt. Materials and Methods: Thirty patien...

متن کامل

Effects of dexmedetomidine on oxygenation and lung mechanics in patients with moderate chronic obstructive pulmonary disease undergoing lung cancer surgery

BACKGROUND Chronic obstructive pulmonary disease (COPD) is a risk factor that increases the incidence of postoperative cardiopulmonary morbidity and mortality after lung resection. Dexmedetomidine, a selective α2-adrenoreceptor agonist, has been reported previously to attenuate intrapulmonary shunt during one-lung ventilation (OLV) and to alleviate bronchoconstriction. OBJECTIVE The objective...

متن کامل

Arterial oxygenation during one-lung ventilation: combined versus general anesthesia.

UNLABELLED The optimal anesthetic management of patients undergoing thoracotomy for pulmonary resection has not been definitely determined. We evaluated whether general i.v. anesthesia (propofol-fentanyl) provides superior PaO2 during one-lung ventilation (OLV) compared with thoracic epidural anesthesia (TEA) with supplemental local and general anesthetics. We studied 60 patients who had prolon...

متن کامل

Comparison of pressure-controlled ventilation with volume-controlled ventilation during one-lung ventilation: a systematic review and meta-analysis

BACKGROUND Not only arterial hypoxemia but acute lung injury also has become the major concerns of one-lung ventilation (OLV). The use of pressure-controlled ventilation (PCV) for OLV offers the potential advantages of lower airway pressure and intrapulmonary shunt, which result in a reduced risk of barotrauma and improved oxygenation, respectively. METHODS We searched Medline, Embase, the Co...

متن کامل

Intravenous Infusion of Dexmedetomidine Combined Isoflurane Inhalation Reduces Oxidative Stress and Potentiates Hypoxia Pulmonary Vasoconstriction during One-Lung Ventilation in Patients

Inhalation anesthetic isoflurane inhibits hypoxia pulmonary vasoconstriction (HPV), while dexmedetomidine (Dex) could reduce the dose of isoflurane inhalation and potentiate HPV, but the mechanism is unclear. Inhibition of reactive oxygen species (ROS) production can favor HPV during one-lung ventilation (OLV). Similarly, nitric oxide (NO), an important endothelium-derived vasodilator in lung c...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:

دوره 130  شماره 

صفحات  -

تاریخ انتشار 2017