Aging performance of a compliant layer bearing acetabular prosthesis in an ovine hip arthroplasty model.
نویسندگان
چکیده
The wear performance of a polyurethane compliant layer (CL) material formed into an acetabular component and implanted into a sheep model of cemented total hip arthroplasty was assessed at 6, 12, 24, and 48 months. Four (11%) of 36 acetabular components debonded from the cement and one component was slightly loose at the cement-bone interface. There was no macroscopic evidence of fracture, wear, or deformation of the CL material on the articular surface of the acetabular components. Small numbers of polymeric wear particles was found in the hip synovial tissues of 10 sheep, most commonly in the early time groups, and were likely associated with initial wear of surface asperities. The wear performance of the CL was unchanged during a 48-month implantation period.
منابع مشابه
Design aspects of compliant, soft layer bearings for an experimental hip prosthesis.
Currently, an artificial hip joint can be expected to last, on average, in excess of 15 years with failure due, in the majority of cases, to late aseptic loosening of the acetabular component. A realistic alternative to the problem of wear in conventional joints is the introduction of bearing surfaces that exhibit low wear and operate in the full fluid-film lubrication regime. Contact analyses ...
متن کاملLong-term evaluation of a compliant cushion form acetabular bearing for hip joint replacement: a 20 million cycles wear simulation.
Soft bearing materials that aim to reproduce the tribological function of the natural joint are gaining popularity as an alternative concept to conventional hard bearing materials in the hip and knee. However, it has not been proven so far that an elastic cushion bearing can be sufficiently durable as a long term (∼20 years) articulating joint prosthesis. The use of new bearing materials should...
متن کاملCementless Hip Arthroplasty in Southern Iran, Midterm Outcome and Comparison of Two Designs
Background: Cementless hip prosthesis was designed to provide biologic fixation, without the use of cement. The second generation components have shown more reliable bone ingrowths and survival rates. We are reporting a midterm result of two designs of cementless prosthesis in a unique culture with different social habits and expectations.Methods: 52 primary cementless total hip arthroplasty in...
متن کاملHip Arthroplasty and its Revision in a Child: Case Report and Literature Review
Juvenile idiopathic arthritis is the leading cause of hip replacement in young children. However, arthroplasty in this population is challenging with several concerns about quality of the growing bone, young age for revision surgery, and difficulties in potential several revisions. In this study we introduce a case of a 12-year old who is one of the youngest patients to undergo revision hip art...
متن کاملاستئوتومی انتهای فوقانی ران برای درمان استئوآرتریت مفصل ران
During the past 20 years, poximal femoral osteotomy has been forgotten because most orthopedic surgeon believed that total hip arthroplasty is the only treatment method for hip joint osteoarthritis. The disadvatages of proximal femoral osteotomy include: Uncertain results, prolonged rehabilitation time after surgery, little improvement in joint ROM and according tosome.euthors difficult subsequ...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
عنوان ژورنال:
- The Journal of arthroplasty
دوره 21 6 شماره