HPLC retention time as a diagnostic tool for hemoglobin variants and hemoglobinopathies: a study of 60000 samples in a clinical diagnostic laboratory.

نویسندگان

  • Alla Joutovsky
  • Joan Hadzi-Nesic
  • Michael A Nardi
چکیده

BACKGROUND Previous evaluations of HPLC as a tool for detection of hemoglobin variants have done so within newborn-screening programs and/or by use of stored samples. We describe a 32-month prospective study in a clinical diagnostic laboratory in which we evaluated the imprecision of HPLC retention times and determined the retention times for hemoglobin variants seen in a multiethnic setting. METHODS We analyzed all samples on the Bio-Rad Variant II HPLC system. For normal hemoglobin fractions and hemoglobin variants, we recorded and analyzed their retention times, their proportion of the total hemoglobin (%), and the peak characteristics. We compared the imprecision of retention time with the imprecision of retention time normalized to the retention time of hemoglobin A0 (Hb A0) and to the retention time of Hb A2. Alkaline and acid hemoglobin electrophoresis, and in certain cases globin chain electrophoresis, isoelectric focusing, and DNA analysis, were performed to document the identities of the hemoglobin variants. RESULTS The mean (SD) imprecision (CV) of the retention time was 1.0 (0.7)% with no statistical difference compared with the imprecision for normalized retention times. Among 60,293 samples tested, we encountered 34 unique hemoglobin variants and 2 tetramers. Eighteen variants and 2 tetramers could be identified solely by retention time and 3 variants by retention time and proportion of total hemoglobin. Four variants could be identified by retention time and peak characteristics and eight variants by retention time and electrophoretic mobility. One variant (Hb New York) was missed on HPLC. Retention time on HPLC was superior to electrophoresis for the differentiation and identification of six members of the Hb J family, four members of the Hb D family, and three variants with electrophoretic mobilities identical or similar to that of Hb C. Six variants with electrophoretic mobilities identical or similar to that of Hb S could be differentiated and identified by retention time and proportion of total hemoglobin. HPLC detected two variants (Hb Ty Gard and Hb Twin Peaks) missed on electrophoresis. CONCLUSIONS The retention time on HPLC is reliable, reproducible, and in many cases superior to conventional hemoglobin electrophoresis for the detection and identification of hemoglobin variants. Confirmatory testing by electrophoresis can be eliminated in the majority of cases by use of retention time, proportion of total hemoglobin, and peak characteristics of HPLC.

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Spectrum of thalassemia and hemoglobinopathies in a tertiary care diagnostic center

Context: Hemoglobinopathies and thalassemias are one of the most common genetic abnormalities prevalent in India and the Middle East. Aim: This study was performed to identify the distribution of abnormal types of hemoglobin (Hb) in a tertiary care diagnostic laboratory. Materials and Methods: An observational study was conducted in the Department of Hematology in a tertiary care diagnostic lab...

متن کامل

Prevalence of Hemoglobin Mutations and Hemoglobinopathies in Masjed Soleiman County, Southeastern Iran

ABSTRACT              Background and Objectives: Hemoglobinopathies are characterized by defects in the synthesis of globin chains of hemoglobin (Hb). The purpose of the present study was to evaluate mutations associated with thalassemia and other hemoglobinopathies in Masjed Soleiman County, Iran.              Methods: This descriptive study was carried out on 456 individuals suspected of ha...

متن کامل

استفاده از روش کاپیلاری الکتروفورز جهت غربالگری اختلالات هموگلوبینی شایع در ایران

Hemoglobinopathies are most common inherited disorders in the world; approximately 7 percent of the worldwide population and 5-6 percent of population of Iran are carriers. The hemoglobin disorders inherit as autosomal recessive and are very common in the Mediterranean area and much of the Asia and Africa. The control of this inherited disorders need to genetic counseling and accurate screening...

متن کامل

Screening for hemoglobinopathies during routine hemoglobin A1c testing using the Tosoh G7 Glycohemoglobin Analyzer.

Approximately 5.1% of the US population has diabetes mellitus, and hemoglobin (Hb) A1c levels are routinely measured to monitor long-term glycemic control in these patients. Many laboratories use ion exchange chromatography for such measurements, and the presence of hemoglobin variants and hemoglobinopathies often results in abnormal peaks on the chromatogram. The goal of this study was to eval...

متن کامل

Detection of Abnormal Hemoglobin Variants by HPLC Method: Common Problems with Suggested Solutions

Thalassemia and thalassemic hemoglobinopathies pose serious health problem leading to severe morbidity and mortality in Indian population. Plethora of hemoglobin variants is prevalent in multiethnic Indian population. The aim of the present study was to analyze laboratory aspects, namely, hematological profile and HPLC findings of the hemoglobin variants detected, and to discuss problems that w...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:
  • Clinical chemistry

دوره 50 10  شماره 

صفحات  -

تاریخ انتشار 2004