Pseudo dislodgement of a stent due to crumpling of a coronary artery: a hitherto unreported complication of the "accordion effect".

نویسندگان

  • Jorge G Allín
  • José A Álvarez
  • Gustavo Leiva
  • Guillermo Migliaro
  • Osvaldo Manuale
  • Pablo Baglioni
چکیده

The "accordion effect" is a mechanical remodeling of the arterial wall produced by endoluminal introduction of stiff guidewires, leading to vessel wall shortening and development of multiple eccentric constrictions. This phenomenon is unresponsive to vasodilators and may lead to unnecessary stenting of the pseudo-lesions. It must be suspected with the development of multiple lesions and when a tortuous artery assumes a linear shape after advancing distally a stiff wire. In the situation of a complete occlusion of the artery the diagnosis may be challenging. Stenting in this scenario can be demanding because of the difficulty to appropriately size the length of the stent to the true lesion. We present a case of an unrecognized accordion phenomenon in an occluded coronary artery with a long dissection treated with two stents that after retrieving the wire were insufficient to cover the whole dissection.

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Stent dislodgement in left anterior descending coronary artery and successful deployment with two parallel wires and a small balloon.

Coronary artery stent dislodgement during angioplasty is a rare complication. Stent dislodgement was more frequent in the past when stents were manually crimped onto the balloon. Newer and improved balloon-mounted stents with better radio-opacity have reduced the incidence of stent dislodgement but do not completely eliminate it. We report a case of balloon-mounted stent dislodgement in the pro...

متن کامل

Management of a large coronary artery aneurysm with graft-coated stent during the acute phase of myocardial infarction

Coronary aneurysms in adults are rare clinical entities. Herein, we presented a 54-year-old man who was admitted with an acute extensive anterior myocardial infarction. The emergency coronary angiography revealed an isolated large aneurysm at the proximal segment of the left anterior descending coronary artery. The patient was successfully treated with a graft-coated stent

متن کامل

Acute and Long Term Outcomes of Coronary Intervention in Unprotected Left Main Lesions

Introduction : Significant left main coronary artery stenosis jeopardizes the entire myocardium of the left ventricle and has the worst prognosis of any form of coronary artery disease. Coronary-artery bypass grafting (CABG) has been considered as the standard therapeutic approach for such patients. There are limited data on the safety and effectiveness of percutaneous coronary intervention (PC...

متن کامل

Coronary accordion effect mimicking coronary dissection

The coronary "accordion" effect is a rare pseudo-complication of percutaneous coronary intervention (PCI). It is usually observed due to straightening and shortening of tortuous vessels with stiff guidewires during PCI. In this case report, we present an interesting case of the coronary accordion effect observed in a 52-year-old woman undergoing PCI.

متن کامل

Successful retrieval of an unexpanded coronary stent from the left main coronary artery during primary percutaneous coronary intervention.

INTRODUCTION Dislodgement and embolization of the new generation of coronary stents before their deployment are rare but could constitute a very serious complication. CASE OUTLINE We report a case of a stent dislodgement into the left main coronary artery during the primary coronary intervention of infarct related left circumflex artery in a patient with acute myocardial infarction. The dislo...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:
  • Archivos de cardiologia de Mexico

دوره 83 4  شماره 

صفحات  -

تاریخ انتشار 2013