Differential growth and development of pigs as assessed by X-ray computed tomography.

نویسندگان

  • L R Giles
  • G J Eamens
  • P F Arthur
  • I M Barchia
  • K J James
  • R D Taylor
چکیده

Data from 54 hybrid (mainly Large White x Landrace) pigs (18 boars, 18 gilts, and 18 barrows) were used to quantify and mathematically describe the differential growth and development of body components of live pigs. The pigs were 32.4 +/- 3.2 kg of BW and 70 +/- 1 d of age (mean +/- SD) at the beginning of the study, were individually penned and fed ad libitum, and were weighed weekly. Computed tomography (CT) imaging was used to determine the weights of lean, fat, bone, and skin tissue in the live pig at 30, 60, 90, 120, and 150 kg of BW. For each target BW, the sum of all the weights of the body components, as assessed by CT, was referred to as CT BW. Linear and nonlinear models were developed to evaluate the patterns of growth and development of each body component relative to CT BW. The correlation between the actual BW and CT BW was close to unity (r = 0.99), indicating that CT scanning could accurately predict the BW of pigs. Across sex and castrate status, percentage of fat (fat weight/CT BW) in the pig was least (11.2%) at the 30-kg target BW and continued to increase to 22.6% by the 150-kg target BW. Percentage of lean, however, was greatest (67.2%) at the 30-kg target BW and continued to decrease to 53.4% by the 150-kg target BW. The sex or castrate status x target BW interaction was significant (P < 0.05) for all the body components, indicating that the developmental patterns were different among sex or castrate status. Barrows were fatter relative to gilts, which in turn were fatter than boars. For lean, the observed pattern for sex or castrate status differences was opposite that for fat. To predict responses to management strategies on growth and development in pigs, accurate mathematical models are required, and the results of this study indicate that the nonlinear (e.g., augmented allometric and generalized nonlinear) functions provided better descriptions of the growth and development of most body components of the live pig than did the simpler (e.g., linear and allometric) models.

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Assessment of X-Ray Crosstalk in a Computed Tomography Scanner with Small Detector Elements Using Monte Carlo Method

Introduction: Crosstalk is a leakage of X-ray or light produced in a matrix of X-ray detectors or array of photodiodes in one element to other elements affecting on image contrast and spatial resolution. In this study, we assessed X-ray crosstalk in a computed tomography (CT) scanner with small detector elements to estimate the effect of various parameters such as X-ray tube voltage, detector e...

متن کامل

Impact of Photon Spectra on the Sensitivity of Polymer Gel Dosimetry by X-Ray Computed Tomography

Introduction: The purpose of the current study was to investigate the effect of X-ray spectra on the sensitivity of a polymer gel dosimeter imaged with a conventional computed tomography (CT) scanner. Material and Methods: The whole process of CT imaging of an irradiated polymer gel was simulated by MCNPX Monte Carlo (MC) code. The imaging of polyacrylamide gel was accomplished by means of a co...

متن کامل

Evaluation of multifunctional targeted gold nanoparticles on X-ray attenuation in nasopharyngeal cancer cells by X- ray imaging

Introduction: Head-and-neck cancer is the sixth most common cancer worldwide with the number of cases consistently increasing in developing countries. Successful development of effective, safe and cost effective nanoprobes for head-and-neck cancer targeting imaging is a big challenge. This study is aimed to develop cysteamine-folate conjugated gold nanoparticles (F-Cys-AuNPs) a...

متن کامل

Evaluation of effect of gold nanorods and spherical gold nanoparticles of different sizes on X-ray attenuation in computed tomography

Introduction: To date, gold nanoparticles (GNPs) have been demonstrated to have great potential as contrast agent for CT imaging and therapeutics. This study was designed to evaluate any effect on X-ray attenuation that might result from using GNPs with a variety of size, surface chemistries and shapes.   Materials and Methods: Spherical GNPs and gold nanorod...

متن کامل

Empirical correlation for porosity deduction from X-ray computed tomography (CT)

For obtaining reservoir petrophysical properties, for example porosity, non-destructive methods such as X-ray computed tomography, CT, seems to be precise and accurate. Porosity is deducted from the CT image with a single scan via different techniques, such as pore space detection by image segmentation techniques then correlation with porosity. More than one hundred samples with carbonate li...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:
  • Journal of animal science

دوره 87 5  شماره 

صفحات  -

تاریخ انتشار 2009