Low cost automated whole smear microscopy screening system for detection of acid fast bacilli

نویسندگان

  • Yan Nei Law
  • Hanbin Jian
  • Norman W S Lo
  • Margaret Ip
  • Mia Mei Yuk Chan
  • Kai Man Kam
  • Xiaohua Wu
چکیده

BACKGROUND In countries with high tuberculosis (TB) burden, there is urgent need for rapid, large-scale screening to detect smear-positive patients. We developed a computer-aided whole smear screening system that focuses in real-time, captures images and provides diagnostic grading, for both bright-field and fluorescence microscopy for detection of acid-fast-bacilli (AFB) from respiratory specimens. OBJECTIVES To evaluate the performance of dual-mode screening system in AFB diagnostic algorithms on concentrated smears with auramine O (AO) staining, as well as direct smears with AO and Ziehl-Neelsen (ZN) staining, using mycobacterial culture results as gold standard. METHODS Adult patient sputum samples requesting for M. tuberculosis cultures were divided into three batches for staining: direct AO-stained, direct ZN-stained and concentrated smears AO-stained. All slides were graded by an experienced microscopist, in parallel with the automated whole smear screening system. Sensitivity and specificity of a TB diagnostic algorithm in using the screening system alone, and in combination with a microscopist, were evaluated. RESULTS Of 488 direct AO-stained smears, 228 were culture positive. These yielded a sensitivity of 81.6% and specificity of 74.2%. Of 334 direct smears with ZN staining, 142 were culture positive, which gave a sensitivity of 70.4% and specificity of 76.6%. Of 505 concentrated smears with AO staining, 250 were culture positive, giving a sensitivity of 86.4% and specificity of 71.0%. To further improve performance, machine grading was confirmed by manual smear grading when the number of AFBs detected fell within an uncertainty range. These combined results gave significant improvement in specificity (AO-direct:85.4%; ZN-direct:85.4%; AO-concentrated:92.5%) and slight improvement in sensitivity while requiring only limited manual workload. CONCLUSION Our system achieved high sensitivity without substantially compromising specificity when compared to culture results. Significant improvement in specificity was obtained when uncertain results were confirmed by manual smear grading. This approach had potential to substantially reduce workload of microscopists in high burden countries.

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Development and evaluation of an automated stainer for acid-fast bacilli.

The current strategy for the control of tuberculosis (TB) relies on early diagnosis, and smear microscopy is an essential component of the laboratory diagnosis of TB in most countries with a high prevalence of the disease. However, even simple smear microscopy examination is far from satisfactory because staining results can vary among individual technicians. In an effort to minimize variations...

متن کامل

Staining techniques for detection of acid fast bacilli: what hope does fluorescein-diacetate (FDA) vitality staining technique represent for the monitoring of tuberculosis treatment in resource limited settings

Despite the recent development of more sensitive technologies, diagnosis of tuberculosis in resource limited settings continues to rely on sputum smear microscopy. This is explained by the fact that smear microscopy is simple, inexpensive, and the most accessible tool in resource limited settings for tuberculosis diagnosis. Hot Ziehl-Neelsen (Z-N) is still used in laboratories of resource limit...

متن کامل

Evaluation of a Novel Biphasic Culture Medium for Recovery of Mycobacteria: A Multi-Center Study

BACKGROUND Mycobacterial culture and identification provide a definitive diagnosis of TB. Culture on Löwenstein-Jensen (L-J) medium is invariably delayed because of the slow growth of M. tuberculosis on L-J slants. Automated liquid culture systems are expensive. A low-cost culturing medium capable of rapidly indicating the presence of mycobacteria is needed. The aim of this study was to develop...

متن کامل

Novel approach for improving sensitivity of microscopic detection of acid-fast bacilli (AFB) by use of the ReaSLR method.

The ReaSLR methodology developed for sputum processing is a novel, low-cost, and simple technique that has improved the sensitivity of smear microscopy for the diagnosis of tuberculosis (TB). Sample processing consists of rapid liquefaction of the sputum specimen with the ReaSLR reagent, followed by syringe filtration, concentration by centrifugation, and use of the sediment for smear microscop...

متن کامل

Modified Bleach Method – Improving Microscopic Detection of Acid Fast Bacilli in Fine Needle Aspiration Smears of Lymph Nodes

Background: Ziehl-Neelsen (ZN) method proves to be a good modality of microscopic detection of Acid Fast Bacilli (AFB) in Fine Needle Aspiration (FNA) smears of lymph nodes though has a low sensitivity. It has a potential to become an even more valuable tool if its sensitivity could be increased. Objective: To improve microscopic detection of AFB in FNA cytology of lymph nodes using modified bl...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:

دوره 13  شماره 

صفحات  -

تاریخ انتشار 2018