Numerical/experimental analysis of the stress field around miniscrews for orthodontic anchorage.
نویسندگان
چکیده
The aims of this study were to analyse the stress distribution developing around an orthodontic miniscrew (OM) inserted into the maxilla and to determine the stress field changes for different screw lengths and for different levels of osseointegration occurring at the bone/screw interface. An integrated experimental/numerical approach was adopted. Using the photoelastic technique, the stress field arising in the bone after screw insertion and the application of the initial orthodontic load was assessed. The finite element (FE) method was used to determine the stress acting in the bony tissue after a given time following screw application, when, for the viscoelastic relaxation effects, the only stress field remaining was that due to the application of the orthodontic load. Different levels of osseointegration were hypothesized. Photoelastic analyses showed that stress distribution does not change significantly for moderate initial orthodontic loads. From the FE simulations, it was found that critical conditions occur for screws 14 mm long with an orthodontic load of 2 N. The optimal screw length seems to be 9 mm. For such a dimension, small stress values were found as well as low risk of lesion to the anatomical structures.
منابع مشابه
Thread Pitch Variant in Orthodontic Mini-screws: A 3-D Finite Element Analysis
Orthodontic miniscrews are widely used as temporary anchorage devices to facilitate orthodontic movements. Miniscrew loosening is a common problem, which usually occurs during the first two weeks of treatment. Macrodesign can affect the stability of a miniscrew by changing its diameter, length, thread pitch, thread shape, tapering angle and so on. In this study, a 3-D finite element analysis wa...
متن کاملEvaluation of primary stability of innovated orthodontic miniscrew system (STS): An ex-vivo study
BACKGROUND Stability is determined as one of the requirements in use of Temporary Anchorage Devices (TAD) in orthodontics. Miniscrew has been a widely used Bone Anchor. Compared with mini-implant that necessitates osseointegration; mechanical retention is a determining factor for primary stability of miniscrew. Studies investigated various ways to increase primary stability. The aim of this stu...
متن کاملFactors Associated with the Success of Orthodontic Miniscrews
Background and aims. Nowadays miniscrews are widely used as skeletal anchorage in orthodontics. However, the success rate of miniscrews is less than that of osseointegrated implants. The aim of this retrospective study was to evaluate factors influencing the success rate of orthodontic miniscrews. Materials and methods. Data of 244 miniscrews in 122 patients (99 females and 23 males, with a mea...
متن کاملFinite element analysis of miniscrew placement in mandibular alveolar bone with varied angulations.
SUMMARY BACKGROUND Titanium miniscrews are increasingly used as orthodontic anchorage. Various factors are known to affect the stability of miniscrew. Placement angle is one of the most controversial issues in this area. Thus, the aim of this finite element study was to evaluate the influence of placement angle and direction of force on the stability of miniscrews. MATERIALS AND METHODS Finit...
متن کاملCorrosion of orthodontic temporary anchorage devices.
Corrosion of orthodontic miniscrews or temporary anchorage devices (TADs) has been proposed as a contributor to inflammation, which in turn is a factor in the clinical success of miniscrews. The purpose of this study was to measure the electrochemical properties of orthodontic miniscrews in artificial saliva with and without fluoride. The corrosion properties of three miniscrew products (Vector...