CellTiter-Glo® 3D: A Sensitive, Accurate Viability Assay for 3D Cell Cultures

نویسنده

  • Michael P. Valley
چکیده

The CellTiter-Glo® 3D Cell Viability Assay is designed for determining cell viability in 3D microtissue spheroids. The assay reagent penetrates large spheroids and has increased lytic capacity—allowing more accurate determination of viability compared to other assay methods. Based on the same chemistry as the classic CellTiter-Glo® Assay, this new 3D assay reagent measures ATP as an indicator of viability, and generates a luminescent readout that is much more sensitive than absorbance or fluorescence-based methods. In addition, the assay protocol is simple and fast, giving results in as little as 30 minutes. Michael P. Valley, Chad A. Zimprich, and Dan F. Lazar. Promega Corporation Publication Date: May 2014, tpub 142 Measuring Cell Viability in Microtissue Spheroids Two-dimensional cell culture has long served as an invaluable tool for in vitro experiments. However, results derived from studying flat monolayers of cells adhered to plastic often do not properly reflect the in vivo situation. Various characteristics of actual tissue, such as morphology, cell-cell communication, gene expression, and biological responsiveness are much better represented by microtissues produced under 3D cell culture conditions that replicate these biological functions. Much effort has gone into the development of the variety of 3D cell culture models available, but little effort has gone into developing the reagents to effectively assay these models. There is a significant risk to data quality in assuming that assays designed for 2D monolayers will work equally well for 3D microtissues, especially considering the increased need for reagent penetration in microtissue spheroids. The CellTiter-Glo® 3D Assay is a new, single-component, liquid reagent for measuring cell viability. The assay has increased lytic capacity and is designed specifically for use with microtissues produced through 3D cell culture. CellTiter-Glo® 3D Assay: Better Microtissue Penetration and Lytic Capacity Initial studies with the classic CellTiter-Glo® Assay demonstrated effective lytic capacity with small microtissues. However, as the microtissues became larger the classic reagent under-reported the total amount of ATP present—as judged by comparison to results from a laborious trichloroacetic acid extraction procedure. Therefore, we optimized the CellTiter-Glo® Assay formulation to increase lytic capacity and generate a new, 3D-optimized bioluminescent cell viability assay. As shown in Table 1, both the classic CellTiter-Glo® and the CellTiter-Glo® 3D Assay reagents recover a similar amount of ATP from small HCT116 colon cancer spheroids (~200 μm diameter), but as the spheroids get larger (> 350 μm diameter), the CellTiter-Glo® 3D Reagent recovers 20–40% more ATP than the classic reagent. We have also observed similar increases in recovery for other cell types, including HEK293 embryonic kidney cells and HepG2 liver carcinoma cells (data not shown). © Promega Corporation, Updated May 2014, tpub 142. http://www.promega.com/pubhub 1 Valley, M., Zimprich, C.A., and Lazar, D.F. Table 1. ATP Detected by the Classic CellTiter-Glo® and CellTiter-Glo® 3D Assays. Different amounts of HCT116 cells (RPMI +10% FBS) were seeded in the InSphero GravityPLUSTM 96-well hanging-drop platform and grown for 4 days. Microtissues were assayed by adding an equal volume of reagent to media volume, shaking for 5 minutes, and recording luminescence after 30 minutes using a GloMax® luminometer. The amount of ATP detected was determined by comparison with ATP standards. ATP Content is Proportional to DNA Content and Viable Cell Number As with the classic CellTiter-Glo® Reagent, the CellTiter-Glo® 3D Reagent generates a luminescent signal that is proportional to the amount of ATP present using pure ATP (Figure 1, Panel A), and the amount of ATP is directly proportional to the number of cells present in 2D cell culture (Figure 1, Panel B). Figure 1. Luminescence generated by the CellTiter-Glo® Assay is proportional to ATP and/or cell number. Panel A. Different concentrations of ATP in water were plated at 100 μl and assayed using the classic CellTiter-Glo® or CellTiter-Glo® 3D Reagents. Panel B. Dilutions of Jurkat cells were prepared in RPMI 1640 with 10% FBS and plated at 100 μl cells per well. An equivalent volume of CellTiter-Glo® 3D Reagent was added to all samples, and after 2 minutes of shaking, the luminescence was recorded at 10 minutes. However, for microtissues in 3D culture, the correlation between cells seeded and luminescent signal is often not linear. For example, with hanging-drop spheroids produced using the InSphero GravityPLUSTM 3D Culture and Assay Platform (Figure 2, Panel A), effects such as contact inhibition on cell proliferation and reduced metabolic activity in the central region of large spheroids cause the relationship between seeded cell number and luminescent signal to be curvilinear (Figure 2, Panel B). However, by including CellToxTM Green Dye, a cell membrane-impermeant fluorogenic DNA-binding dye, in our lytic assay we can show that as microtissue size increases, the amount of ATP detected (luminescence, RLU) by the CellTiter-Glo® 3D Assay is proportional to the amount of DNA detected (fluorescence, RFU; Figure 2, Panel C). This confirms that the CellTiter© Promega Corporation, Updated May 2014, tpub 142. http://www.promega.com/pubhub 2 Valley, M., Zimprich, C.A., and Lazar, D.F. Glo® 3D Assay is effectively lysing cells, resulting in release of ATP, and can accurately report the number of viable cells in microtissues produced through 3D cell culture. Figure 2. Seeding density vs. size, ATP content and DNA content. Panel A. Differential contrast images of HCT116 colon cancer spheroids grown for 4 days in the InSphero GravityPLUSTM 96-well hanging-drop platform after seeding with 400, 800, 1600, 2400, 3200, 4800, 6400, or 8000 cells. Images were acquired in an InSphero GravityTRAPTM plate. Panels B and C. An equivalent volume of CellTiter-Glo® 3D Reagent was added to all samples, and after 5 minutes of shaking, luminescence and/or fluorescence was recorded at 30 minutes. In Panel C, a 2X concentration of CellToxTM Green Dye was added to the CellTiterGlo® 3D Reagent prior to sample addition. CellTiter-Glo® 3D Assay Performance Relative to Other Viability Assays The CellTiter-Glo® 3D Assay is significantly brighter than a competing bioluminescent ATP detection assay for measuring cell viability (Figure 3, Panel A). As shown in Table 2, this difference is due to the recovery of considerably more ATP from both small and large microtissues by the CellTiter-Glo® 3D Reagent. This is likely due (in part) to greater preservation of the ATP because of the composition of the CellTiter-Glo® 3D Reagent, but also to a striking difference in lytic effectiveness (Figure 3, Panel B). When CellToxTM Green Dye is added to each reagent prior to addition to the spheroid samples, confocal laser fluorescent microscopy of ~300 μm HCT116 spheroids illustrates that the CellTiter-Glo® 3D Reagent penetrates almost completely through the entire spheroid thickness. In contrast, the competitor reagent only penetrates the outer third of the same-sized spheroids. © Promega Corporation, Updated May 2014, tpub 142. http://www.promega.com/pubhub 3 Valley, M., Zimprich, C.A., and Lazar, D.F. Figure 3. Lytic capacity of CellTiter-Glo® 3D compared to ATPlite 1Step Reagent. HCT116 colon cancer spheroids were generated by seeding cells in the InSphero GravityPLUSTM 96-well hanging-drop platform and grown for 4 days. Panel A. An equivalent volume of reagent was added to all samples, and after 5 minutes of shaking, luminescence was recorded at 30 minutes. Panel B. A 2X concentration of CellToxTM Green Dye was added to each CellTiter-Glo® 3D Reagent (left) or ATPliteTM 1Step Reagent (right) prior to sample addition, and after 5 minutes of shaking, the confocal laser fluorescent microscopy images were acquired at 30 minutes using Ex/Em: 488/520nm. The spheroids in Panel B are ~300 μm in diameter, and the bars in each image represent a distance of 200 μm. Table 2. ATP Detected by the ATPliteTM 1Step and CellTiter-Glo® 3D Assays. Different amounts of HCT116 cells (RPMI +10% FBS) were seeded in the InSphero GravityPLUSTM 96-well hanging-drop platform and grown for 4 days. Microtissues were assayed by adding an equal volume of reagent to medium, shaking for 5 minutes and recording luminescence after 30 minutes with a GloMax® luminometer. The amount of ATP detected was determined by comparison with ATP standards. Greater Sensitivity, Shorter Protocol © Promega Corporation, Updated May 2014, tpub 142. http://www.promega.com/pubhub 4 Valley, M., Zimprich, C.A., and Lazar, D.F. In common with many bioluminescent assays, the CellTiter-Glo® 3D Assay exhibits a signal that is orders of magnitude above background (Figure 4). In contrast, other non-lytic viability assays that measure changes in fluorescence (e.g., alamarBlue®) or absorbance (e.g., MTT) generate signals that are only modestly higher than their no-cell control signals. In addition to this enhanced sensitivity, the CellTiter-Glo® 3D Assay has a much shorter assay time. The luminescent assay can be measured in 30 minutes or less, whereas alamarBlue® and MTT assays typically require multiple-hour incubations. Figure 4. Performance of the CellTiter-Glo® 3D Assay compared to other viability assays. Signal-to-background ratios for the luminescent CellTiter-Glo® 3D Assay compared to fluorescence (alamarBlue®) and absorbance (MTT) assays. Panel A. HCT116 colon cancer cells (~340 μm) grown for 4 days in the InSphero GravityPLUSTM 96-well hanging-drop platform. Panel B. InSphero human liver microtissues (~250 μm). All microtissues were assayed according to the assay manufacturers protocols. Total assay times for the CellTiter-Glo® 3D, alamarBlue®, and MTT assays were 30 minutes, 3 hours, and 8 hours, respectively. Summary The CellTiter-Glo® 3D Assay is a new, validated bioluminescent assay for measuring the viability of cells produced through 3D cell culture. It provides a fast, easy-to-use, single-component liquid reagent with superior lytic capacity for greater preservation of ATP and enhanced penetration into 3D microtissues. This new reagent is more robust than our classic CellTiter-Glo® Assay or competing ATP viability assays and offers superior sensitivity for 3D cell culture. HOW TO CITE THIS ARTICLE Scientific Style and Format, 7th edition, 2006 Valley, M., Zimprich, C.A., and Lazar, D.F. CellTiter-Glo® 3D: A Sensitive, Accurate Viability Assay for 3D Cell Cultures. [Internet] May 2014, tpub 142. [cited: year, month, date]. Available from: http://www.promega.com/resources/pubhub/a-cell-viability-assay-for-3dcultures/ American Medical Association, Manual of Style, 10th edition, 2007 Valley, M., Zimprich, C.A., and Lazar, D.F. CellTiter-Glo® 3D: A Sensitive, Accurate Viability Assay for 3D Cell Cultures. Promega Corporation Web site. http://www.promega.com/resources/pubhub/a-cell-viability-assay-for-3d-cultures/ Updated May 2014, tpub 142. Accessed Month Day, Year. © Promega Corporation, Updated May 2014, tpub 142. http://www.promega.com/pubhub 5 Valley, M., Zimprich, C.A., and Lazar, D.F. CellTiter-Glo and GloMax are registered trademarks of Promega Corporation. CellTox is a trademark of Promega Corporation. alamarBlue is a registered trademark of Life Technologies Corporation. GravityPLUS is a trademark of InSphero AG. © Promega Corporation, Updated May 2014, tpub 142. http://www.promega.com/pubhub 6 Valley, M., Zimprich, C.A., and Lazar, D.F.

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Dilemmas in the reliable estimation of the in-vitro cell viability in magnetic nanoparticle engineering: which tests and what protocols?

Magnetic nanoparticles [MNPs] made from iron oxides have many applications in biomedicine. Full understanding of the interactions between MNPs and mammalian cells is a critical issue for their applications. In this study, MNPs were coated with poly(ethylenimine) [MNP-PEI] and poly(ethylene glycol) [MNP-PEI-PEG] to provide a subtle difference in their surface charge and their cytotoxicity which ...

متن کامل

Biological Effect of Modern Fetal Ultrasound Techniques on Human Dermal Fibroblast Cells

Background: Diagnostic ultrasound has been used to detect human disease especially fetus abnormalities in recent decades. Although the harmful effects of diagnostic ultrasound on human have not been established so far, several researchers showed it has had bioeffects in cell lines and in experimental animals. Three-dimensional (3D), four-dimensional (4D), and color Doppler sonography are new te...

متن کامل

A high-throughput, multiplex cell death assay using an RNAi screening approach.

This protocol outlines a high-throughput, multiplex cell death assay and its use in conjunction with a genome-scale siRNA screen to identify genes that cooperate with a drug to induce apoptosis. The assay, ApoLive-Glo (Promega), measures viability of drug-treated, reverse-transfected cells via the fluorescent CellTiter-Fluor reagent, which includes a substrate that is cleaved by a live cell pro...

متن کامل

The Viability of Human Testis-Derived Cells on Human Serum Albumin-Based Scaffold as An Artificial Male Germ Cell Niche

Azoospermia is one of the challenging disorders affecting couples who are afflicted with infertility. Human testisderivedcells (hTCs) are suitable candidates for the initiation of in-vitro spermatogenesis for these types of patients.The current study aimed to assess the proliferation of hTCs through the cell culture on the three-dimensional (3D) porousscaffolds. Cells harveste...

متن کامل

Toxicity of used orthodontic archwires assessed by three-dimensional cell culture.

The aim of the present study was to determine whether used orthodontic wires made of different materials cause toxicity and loss of viability on three-dimensional (3D) cell cultures. Three types of orthodontic wires, stainless steel, Nitinol, and TMA (n = 9) which had been used clinically in fixed appliances for a period of 1 month, were retrieved at random from five patients. Both upper and lo...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:

دوره   شماره 

صفحات  -

تاریخ انتشار 2014