A Feasibility Study in Measuring Soft Tissue Artifacts on the Upper Leg Using Inertial and Magnetic Sensors
نویسندگان
چکیده
Soft-tissue artifacts cause inaccurate estimates of body segment orientations. The inertial sensor (or optical marker) is orientating (or displacing) with respect to the bone it has to measure, due to muscle and skin movement [1]. In this pilot study 11 inertial and magnetic sensors (MTw, Xsens Technologies) were placed on the rectus femoris, vastus medialis and vastus lateralis (upper leg). One sensor was positioned on the tendon plate behind the quadriceps (iliotibial tract, as used in Xsens MVN [1]) and used as reference sensor. Walking, active and passive knee extensions and muscle contractions without flexion/extension were recorded using one subject. The orientation of each sensor with respect to the reference sensor was calculated. During walking, relative orientations of up to 28.6o were measured (22.4±3.6o). During muscle contractions without flexion/extension the largest relative orientations were measured on the rectus femoris (up to 11.1o) [2]. This pilot showed that the ambulatory measurement of deformation of the upper leg is feasible; however, improving the measurement technology is required. We therefore have designed a new inertial and magnetic sensor system containing smaller sensors, based on the design of an instrumented glove for the assessment of hand kinematics [3]. This new sensor system will then be used to investigate soft-tissue artifacts more accurately; in particular we will focus on in-use estimation and elimination of these artifacts.
منابع مشابه
Effectiveness of the gastrocsoleous flap for coverage of soft tissue defects in leg with emphasis on the distal third
Introduction: The standard methods for reconstruction of soft tissue defects in legs are gastrocnemius flap for proximal third defects, soleus flap for middle third and free flap in the distal third. However, there are problems with the use of free flap, like increased operative time, damage of major vessels and the need for experienced microsurgeon. In this study we examined the ability of the...
متن کاملEffectiveness of the Gastrocsoleous Flap for Coverage of Soft Tissue Defects in Leg with Emphasis on the Distal Third
Background: The standard methods for reconstruction of soft tissue defects in the leg include gastrocnemius flap for proximal third defects, soleus flap for middle third and free flap in the distal third. However, there are problems with the use of free flap, like increased operative time, damage of major vessels and the need for experienced microsurgeon. Mathods: This prospective study was und...
متن کاملA Real-time Motion Tracking Wireless System for Upper Limb Exosuit Based on Inertial Measurement Units and Flex Sensors (TECHNICAL NOTE)
This paper puts forward a real-time angular tracking (motion capture) system for a low cost upper limb exosuit based on sensor fusion; which is integrated by an elastic sleeve-mitten, two inertial measurement units (IMU), two flex sensors and a wireless communication system. The device can accurately detect the angular position of the shoulder (flexion-extension, abduction-adduction and interna...
متن کاملDistally Based Sural Artery Flap: A Workhorse to Cover the Soft Tissue Defects of Distal Leg, Ankle and Foot
Background & Aims: Distal leg, ankle and foot injuries are relatively common; and because of lack of soft tissue and poor blood supply in these areas, one of the common problems in these patients is soft tissue necrosis. Exposed orthopedic implants can be used as open reduction internal fixator (ORIF) in these regions. Methods: During 2013-2014, 14 patients (11 men and 3 women) with a mean age ...
متن کاملSynchronous Soleus and Reverse Sural Flap for Large Soft Tissue Defect Reconstruction of Leg
BACKGROUND Extended Soft tissue defect of leg including middle and distal parts always has been a challenge for many plastic surgeons and also a frustrated problem for patients and families. To introduce the use of the soleus muscle and reverse sural flaps as synchronous surgical treatment alternative of the leg bone exposure with large soft tissue defect, this study was conducted. METHODS T...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
عنوان ژورنال:
دوره شماره
صفحات -
تاریخ انتشار 2012