Characterization of X-ray area detectors for synchrotron beamlines.

نویسنده

  • Cyril Ponchut
چکیده

In order to deal with the problem of quantitative and consistent evaluation of two-dimensional X-ray detectors at synchrotron beamlines, the methodology for X-ray area detector characterization is reviewed. It is based on the definition of a minimum yet complete set of imaging parameters able to describe any kind of two-dimensional detector regardless of its operating range, field of application and detecting principle. Measuring and derivation methods are reviewed for each parameter. Imaging parameters are to a large extent directly exploitable to assess the performance of a detector for any scientific application. Imaging characterization aims at helping two-dimensional detector developers and two-dimensional detector users in defining or choosing the device best suited for a given application, based on quantitative arguments.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Development of optical choppers for time-resolved measurements at soft X-ray synchrotron radiation beamlines

Two types of optical choppers for time-resolved measurements at synchrotron radiation soft X-ray beamlines have been developed. One type uses an air-spindle-type rotation mechanism with a two-stage differential pumping system to maintain the ultra-high vacuum of the X-ray beamline, and the other uses a magnetic bearing. Both can be installed at the soft X-ray beamlines at SPring-8, greatly impr...

متن کامل

TomoPy: a framework for the analysis of synchrotron tomographic data

Analysis of tomographic datasets at synchrotron light sources (including X-ray transmission tomography, X-ray fluorescence microscopy and X-ray diffraction tomography) is becoming progressively more challenging due to the increasing data acquisition rates that new technologies in X-ray sources and detectors enable. The next generation of synchrotron facilities that are currently under design or...

متن کامل

Collecting data in the home laboratory: evolution of X-ray sources, detectors and working practices

While the majority of macromolecular X-ray data are currently collected using highly efficient beamlines at an ever-increasing number of synchrotrons, there is still a need for high-performance reliable systems for in-house experiments. In addition to crystal screening and optimization of data-collection parameters before a synchrotron trip, the home system allows the collection of data as soon...

متن کامل

Synthesis and characterization of Gd2O2 S: Tb3+ phosphor powder for X-ray imaging detectors

Gadolinium oxysulfide phosphor doped with trivalent terbium have been synthesized using urea homogenous precipitation and followed by sulfurization at 800 °C under argon atmosphere. Structural and morphological of synthesized phosphor powder were characterized by x-ray diffraction (XRD), scanning electron microscopy (SEM) and Fourier transform infrared spectrometry (FT-IR). Hexagonal structure ...

متن کامل

MAXIPIX, a fast readout photon-counting X-ray area detector for synchrotron applications

A 2D photon-counting X-ray detector system with 1.4 kHz frame rate and 55 μm spatial resolution has been developed and commissionned on ESRF beamlines. The system called MAXIPIX (Multichip Area X-ray detector based on a photon-counting PIXel array) consists of a detector module implementing up to five MEDIPIX-2 or TIMEPIX photon-counting readout chips, a custom readout interface board and a Lin...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Journal of synchrotron radiation

دوره 13 Pt 2  شماره 

صفحات  -

تاریخ انتشار 2006