3D Elbow Kinematics with Monoplanar Fluoroscopy: In Silico Evaluation

نویسندگان

  • Luca Tersi
  • Silvia Fantozzi
  • Rita Stagni
چکیده

An in-silico assessment of the performance of 3D video-fluoroscopy for the analysis of the kinematics of long bones is proposed. A reliable knowledge of in-vivo joints kinematics in physiological conditions is fundamental in the clinical field. 3D videofluoroscopy theoretically permits a mm/deg level of accuracy in joint motion analysis, but the optimization algorithm for the pose estimation is highly dependent on the geometry of the bone segment analyzed. An automated technique based on distance maps and tangency condition was applied to the elbow bones. The convergence domain was explored to quantify and optimize measurement accuracy in terms of bias and precision. By conditioning the optimization algorithm using simple image features, the estimation error had small dispersion (interquartile range within 0.5 and 0.025 mm/deg for out-of-plane and in-plane pose parameters, resp.), but with occasional bias and outliers. 3D video-fluoroscopy produced promising results for the elbow joint, but further in-vitro validation studies should be carried out.

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

3D Kinematics Analysis of Overhead Backhand and Forehand Smash Techniques in Badminton

Background. This study aims to analyze the movement of backhand and forehand smash stroke techniques in badminton in three dimensions using a kinematics approach. Objectives. The obtained results were analyzed using a descriptive and quantitative approach. Methods. Furthermore, 24 male badminton players from the university student activity unit with an average age of 19.4 ± 1.6 years, height ...

متن کامل

Quantification of the Performance of Mono- and Bi-planar 3d Fluoroscopy Compared to Marker-based Rsa

Accurate knowledge of joint kinematics is fundamental for research and clinical purposes. Radiologic based joint kinematic estimation technique have been recently used to study intact joint in-vivo kinematics. Bi-planar methods are more accurate but expensive and invasive, while mono-planar ones are less reliable but more suitable for the clinical practice. The aim of the present work is to qua...

متن کامل

Elbow position affects distal radioulnar joint kinematics.

PURPOSE Previous in vivo and in vitro studies of forearm supination-pronation suggest that distal radioulnar joint kinematics may be affected by elbow flexion. The primary hypotheses tested by this study were that, in vivo, ulnar variance changes with elbow flexion and forearm rotation, and the arc of forearm rotation changes in relationship to elbow flexion. METHODS Changes in radioulnar kin...

متن کامل

Validation of a voxel-based 2D to 3D registration method for measuring 3D natural ankle kinematics with single plane fluoroscopy

Introduction In vivo three-dimensional (3D) kinematics of the ankle joint is essential for a better understanding of its biomechanics and for many clinical applications. Several measurement techniques are available for this data, but few allow non-invasive measurements with sub-millimetre accuracy. The purposes of the study were to develop further a voxel-based 2D to 3D registration method [1] ...

متن کامل

2D-3D Registration of CT Vertebra Volume to Fluoroscopy Projection: A Calibration Model Assessment

This study extends a previous research concerning intervertebral motion registration by means of 2D dynamic fluoroscopy to obtain a more comprehensive 3D description of vertebral kinematics. The problem of estimating the 3D rigid pose of a CT volume of a vertebra from its 2D X-ray fluoroscopy projection is addressed. 2D-3D registration is obtained maximising a measure of similarity between Digi...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:
  • EURASIP J. Adv. Sig. Proc.

دوره 2010  شماره 

صفحات  -

تاریخ انتشار 2010