MSL Technical Guide 32 An accurate RF reference signal for testing power measuring instruments

ثبت نشده
چکیده

Providing an accurate reference signal for such calibration work is not always easy. The output characteristics of a signal generator are difficult to measure and the cable, or network, used to connect the device under test to a generator will also affect the power level seen at the device. If these effects cannot be accounted for properly, the accuracy of the reference level will be limited.

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Personal computer-based electrical power quality signal generator

Electrical power quality signal generator, capable of reproducing power quality disturbances in accordance with European quality standard EN50160, is presented in this paper. Signal generator is divided in two parts: LabVIEW based virtual instrumentation software for defining the disturbance parameters and hardware electronics for signal generation (data acquisition card and power amplifier). T...

متن کامل

Estimation of harmonic interference parameters of surface-NMR signal using an adaptive method and residual signal power

Surface nuclear magnetic resonance (surface-NMR) method is a well-known tool for determining the water-bearing layers and subsurface resistivity structure. Harmonic interference is an inevitable interference in surface-NMR measurements. Accurate estimation of harmonic interference parameters (i.e., fundamental frequency, phase and amplitude) leads to better retrieval of power-line harmonics and...

متن کامل

Sensorless Model Reference Adaptive Control of DFIG by Using High Frequency Signal Injection and Fuzzy Logic Control

In this paper, a new sensorless model reference adaptive method is used for direct control of active and reactive power of the doubly fed induction generator (DFIG). In order to estimate the rotor speed, a high frequency signal injection scheme is implemented. In this study, to improve the accuracy of speed estimation, two methods are suggested. First, the coefficients of proportional-integral ...

متن کامل

FPGA Implementation of a Hammerstein Based Digital Predistorter for Linearizing RF Power Amplifiers with Memory Effects

Power amplifiers (PAs) are inherently nonlinear elements and digital predistortion is a highly cost-effective approach to linearize them. Although most existing architectures assume that the PA has a memoryless nonlinearity, memory effects of the PAs in many applications ,such as wideband code-division multiple access (WCDMA) or orthogonal frequency-division multiplexing (OFDM), can no longer b...

متن کامل

Nonlinear Modelling of Kerman Combined Cycle Power Plant Drum-Boiler and Drum Level control especially in trip conditions

There are various methods of power generation such as combined cycle power plants. There are many variables in a power plant boiler unit, but the most important variables are Pressure and specially drum level that control system should be put it in the safe range. The purpose of this article is, modifying the oscillatory behavior of the drum level of Kerman combined cycle power plant and especi...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:

دوره   شماره 

صفحات  -

تاریخ انتشار 2014