The Strain at Bone-Implant Interface Determines the Effect of Spinopelvic Reconstruction following Total Sacrectomy: A Strain Gauge Analysis in Various Spinopelvic Constructs

نویسندگان

  • Yan Yu
  • Rui Zhu
  • Zhi-Li Zeng
  • Yong-Wei Jia
  • Zhou-Rui Wu
  • Yi-Long Ren
  • Bo Chen
  • Zu-Quan Ding
  • Li-Ming Cheng
چکیده

PURPOSE There is still some controversy regarding the optimal biomechanical concept for spinopelvic stabilization following total sacrectomy for malignancy. Strains at specific anatomical sites at pelvis/sacrum and implants interfaces have been poorly investigated. Herein, we compared and analyzed the strains applied at key points at the bone-implant interface in four different spinopelvic constructs following total sacrectomy; consequently, we defined a balanced architecture for spinopelvic fusion in that situation. METHODS Six human cadaveric specimens, from second lumbar vertebra to proximal femur, were used to compare the partial strains at specific sites in a total sacrectomy model. Test constructs included: (1) intact pelvis (control), (2) sacral-rod reconstruction (SRR), (3) bilateral fibular flap reconstruction (BFFR), (4) four-rods reconstruction (FRR), and (5) improved compound reconstruction (ICR). Strains were measured by bonded strain gauges onto the surface of three specific sites (pubic rami, arcuate lines, and posterior spinal rods) under a 500 N axial load. RESULTS ICR caused lower strains at specific sites and, moreover, on stress distribution and symmetry, compared to the other three constructs. Strains at pubic rami and arcuate lines following BFFR were lower than those following SRR, but higher at the posterior spinal rod construct. The different modes of strain distribution reflected different patient's parameter-related conditions. FRR model showed the highest strains at all sites because of the lack of an anterior bracing frame. CONCLUSIONS The findings of this investigation suggest that both anterior bracing frame and the four-rods load dispersion provide significant load sharing. Additionally, these two constructs decrease the peak strains at bone-implant interface, thus determining the theoretical surgical technique to achieve optimal stress dispersion and balance for spinopelvic reconstruction in early postoperative period following total sacrectomy.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

The Role of Spinopelvic Parameters in Clinical Outcomes of Spinal Osteotomies in Patients with Sagittal Imbalance

Background: Sagittal imbalance is known as the main radiographic driver of disability in adult spinal deformity (ASD).In this study, the association of radiological spinopelvic parameters and clinical outcomes was evaluated following thecorrective surgery of sagittal imbalance, in order to explore the predictive ability of each parameter.Methods: A total of 23 patients, who underwent corrective...

متن کامل

Pelvic Reconstruction Surgery Using a Dual-Rod Technique with Diverse U-Shaped Rods After Posterior En Bloc Partial Sacrectomy for a Sacral Tumor: 2 Case Reports and a Literature Review.

BACKGROUND Spinopelvic reconstruction after sacrectomy for a sacropelvic tumor can result in various complications and requires a highly complicated surgical technique. We report 2 cases of pelvic reconstruction surgery using diverse U-shaped rods (USRs) after partial sacrectomy. CASE DESCRIPTION A partial sacrectomy was performed for 2 different cases: one case was a metastatic sacral tumor ...

متن کامل

Management of Sacral Tumors Requiring Spino-Pelvic Reconstruction with Different Histopathologic Diagnosis: Evaluation with Four Cases

In this retrospective study, surgical results of four patients with sacral tumors having disparate pathologic diagnoses, who were treated with partial or total sacrectomy and lumbopelvic stabilization were abstracted. Two patients were treated with partial sacral resection and two patients were treated with total sacrectomy and spinopelvic fixation. Fixation methods included spinopelvic fixatio...

متن کامل

Spinopelvic tumor resection and reconstruction.

How are spinopelvic tumor resections classified? The type of pelvic resection depends on the area involved and the extent of the tumor. Problems arise when the tumor involves the sacrum and the lower lumbar spine. To obtain acceptable surgical margins in these cases, skeletal resection should extend beyond the standard hemipelvectomy (ie, the sacroiliac joint) and may include the ilium, part of...

متن کامل

Effect of Abutment Angulation and Material on Stress and Strain Distributions in Premaxillary Bone: A Three-Dimensional Finite Element Analysis

Background and Aim: Dental implants with angled abutments are often inserted in the anterior maxillary region due to the status of the residual ridge and aesthetic considerations. The purpose of this study was to assess stress and strain distributions in the premaxillary bone around dental implants by means of finite element analysis (FEA). Materials and Methods: Four three-dimensional (3D) fi...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره 9  شماره 

صفحات  -

تاریخ انتشار 2014