Evaluation of the analytical performance of the coulometry-based Optium Omega blood glucose meter.
نویسندگان
چکیده
BACKGROUND The goal of diabetes treatment is maintaining near normoglycemia based on self-monitoring of blood glucose (SMBG). In this study, an evaluation of the analytical performance of the coulometry-based Optium Omega™ glucose meter designed for SMBG has been carried out. METHODS The assessment of precision and between-lot variability was based on glucose measurements in ethylene-diaminetetraacetic acid venous blood samples. Glucose concentrations measured in 289 fresh capillary blood samples using the Omega glucose meter and the Biosen C_line analyzer were compared. RESULTS Within-run imprecision coefficient of variation for the lower and higher glucose concentrations amounted to 5.09 and 2.1%, respectively. The relative lot-dependent differences found for the lower and higher glucose concentrations were equal to 6.8 and 2.6%, respectively. The glucose meter error calculated for various concentration ranges amounted from 2.22 to 4.48%. The glucose meter error met the accuracy criteria recommended by the International Organization for Standardization and the American Diabetes Association. The Passing-Bablok agreement test and error grid analysis with 96% of results in zone A indicated good concordance of results, including glucose concentrations below 100 mg/dl. CONCLUSIONS The evaluated Optium Omega glucose meter fits the analytical requirements for its use in blood glucose monitoring in diabetes patients.
منابع مشابه
Evaluation of the analytical performance of the coulometry-based Optium Omega blood glucose meter: what do such evaluations show?
The article entitled "Evaluation of the Analytical Performance of the Coulometry-Based Optium Omega Blood Glucose Meter", by Solnica and colleagues in this issue of Journal of Diabetes Science and Technology demonstrates that the Optium Omega blood glucose meter meets the analytical requirements for glucose meter performance and it is stated that the results are clinically useful. The authors s...
متن کاملFreeStyle Lite--a blood glucose meter that requires no coding.
BACKGROUND Abbott Diabetes Care introduced the FreeStyle Lite blood glucose monitoring system, which simplifies the management of diabetes. The FreeStyle Lite system relies on FreeStyle technology but eliminates the need for coding the meter for individual strip lots. The meter is precoded for the FreeStyle Lite strips. FreeStyle systems use coulometry technology where the glucose signal is cal...
متن کاملAnalytical Performance and Quality Control of a Glucose Monitor System
Background and Objective: The reliability and validity of monitors for self-monitoring of blood glucose are debated. We evaluated the analytical performance of Accu-check Active (Boehringer Mannheim, Roche) which is one of the most commonly used monitors in Iran. Material and Methods: We compared the monitor readings with the reference values by percentage of values within...
متن کاملComparison of Two Veterinary Blood Glucose Meters and One Human-Based Glucose Meter for Use in Dogs
Background: Recently, tendency to use veterinary specific Portable blood glucose meter (PBGMs) has increased. However, assessment of their analytical and clinical accuracy is a matter of concern. OBJECTIVES: To assess accuracy of two veterinary (AlphaTRAK2 and CERA-PET) and one human-based (Bionime) PBGMs for canine blood samples. METHODS: In this cross-sectional study, a total of 160 client-ow...
متن کاملTighter accuracy standards within point-of-care blood glucose monitoring: how six commonly used systems compare.
INTRODUCTION Blood glucose monitoring systems (BGMS) are used in the hospital environment to manage blood glucose levels in patients at the bedside. The International Organization for Standardization (ISO) 15197:2003 standard is currently used by regulatory bodies as a minimum requirement for the performance of BGMS, specific to self-testing. There are calls for the tightening of accuracy requi...