Undisplaced Intraoperative Fracture Presenting as Early Dislocation with Tapered Wedge Stems in Total Hip Arthroplasty - Case Series and Review of Literature

نویسندگان

  • A V Gurava Reddy
  • Krishna Kiran Eachempati
  • Aakash Mugalur
  • A Suchinder
  • V B N Prasad Rao
  • Nalanda Kamurukuru
چکیده

INTRODUCTION Periprosthetic fractures and dislocation in the early post-operative period can be disastrous both for the surgeon and the patient. However, undisplaced periprosthetic fractures presenting with dislocation is uncommon. We describe successful management of two cases (one bilateral dislocation and one unilateral dislocation) of undisplaced iatrogenic fractures in total hip arthroplasty (THA) presenting as early dislocation. CASE REPORT Case 1 was a 45-year-old female with osteoarthritis of hip secondary to developmental dysplasia of the hip with bilateral early nontraumatic dislocation with bilateral identical periprosthetic fracture. It was managed by revision to long stem and encirclage wiring. Case 2 presented with early dislocation in the 2nd week post THA. We found an intertrochanteric fracture intra-operatively with unstable implant. Acetabular component and femoral component revision were done with reconstruction of the greater trochanter. DISCUSSION These fractures could be occult iatrogenic fractures characteristic of taper wedge stems which presented as early nontraumatic dislocation in the post-operative period. The prosthesis subsidence, loss of muscle tension and change of version might be the factors leading to dislocation. CONCLUSION Unrecognized incomplete intraoperative fracture can occur with tapered wedge uncemented stems which can present as a dislocation in the immediate post-operative period. This will require early revision of the femoral component.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Fatal Cobalt Cardiomyopathy Following Revision Total Hip Arthroplasty – A Brief Report with Review of Literature

Ceramic bearing surfaces are being increasingly used in young patients undergoing total hip arthroplasty. However,failures have been reported including fractures even with the newer third generation ceramics. The recommendedtreatment for fracture of ceramic bearing surfaces is complete synovectomy and revision total hip arthroplasty.However, disappointing results have also bee...

متن کامل

Cementless Total Hip Arthroplasty After an Iatrogenic Subtrochanteric Fracture due to Hardware Removal: A Case Report

Introduction: Total hip arthroplasty (THA) after proximal femoral fixation is a challenging procedure due to possible hardware-related complications. Case presentation: A 78-year-old female with hip osteoarthritis had a proximal femoral osteotomy fixed using a blade plate in the same femur 41 years ago. A two-step approach was planned. After a challenging...

متن کامل

Primary Cementless Hip Arthroplasty in Unstable Intertrochanteric Femur Fracture in Elderlys: Short-term Results

PURPOSE This study was aimed to explore and report the short term results of primary cementless hip arthroplasty in treatment of unstable intertrochanteric femur fracture in elderlys. MATERIALS AND METHODS Between March 2009 and Feburary 2012, 35 arthroplasty cases performed by single surgeon and followed up for more than one year were evaluated. They were 21 females and 14 males with mean ag...

متن کامل

Epidemiology of periprosthetic femoral fractures in 5417 revision total hip arthroplasties: a 40-year experience.

AIMS The goals of this study were to define the risk factors, characteristics, and chronology of fractures in 5417 revision total hip arthroplasties (THAs). PATIENTS AND METHODS From our hospital's prospectively collected database we identified all patients who had undergone a revision THA between 1969 and 2011 which involved the femoral stem. The patients' medical records and radiographs wer...

متن کامل

Four- to six-year follow-up of primary THA using contemporary titanium tapered stems.

Tapered cementless femoral components have been used in total hip arthroplasty constructs for more than 20 years. In the past 5 to 10 years, these stems have gained popularity in the United States. The purpose of this study was to evaluate the results of the authors’ initial experience using a contemporary tapered, proximally porous-coated, titanium femoral component at 4 to 6 years of follow-u...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره 7  شماره 

صفحات  -

تاریخ انتشار 2017