Results for serum cholesterol and triglycerides by gas-liquid chromatography, as compared with a continuous-flow technique.

نویسندگان

  • R Watts
  • T Carter
  • S Taylor
چکیده

We assessed the usefulness of gas-liquid chromatography forthe routine and reference measurement of cholesterol and triglycerides (triacylglycerols). Compared with results obtained by an AutoAnalyzer II method, correlation was good with both serum specimens (triglycerides, r = 0.88; cholesterol, r = 0.90) and lipoprotein fractions isolated by ultracentrifugation (triglycerides, r = 0.98; cholesterol, r = 0.98). However, none of the comparisons was completely free of analytical bias, and in general the AutoAnalyzer method underestimated the cholesterol value and overestimated triglycerides. The obvious advantage of the AutoAnalyzer is its greater analytical speed, but the chromatographic method appeared to be more accurate and precise and to suffer less from interfering substances, and in addition gave information about the cholesterol ester and triglyceride composition. We expect gas-liquid chromatography to be of major importance in the calibration of other analytical methods.

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Variables in the measurement of serum cholesterol by gas-liquid chromatography.

Gas-liquid chromatography (GLC) is an effective method for the measurement of total serum cholesterol. Its use in the clinical laboratory, however, requires careful attention to many variables (flow rate, sample size, sensitivity of solvent and choice of the quantitation method, i.e. peak-height ratio vs. peak height). This report evaluates the effect of these variables on the quantitation of s...

متن کامل

Comparative Study of Continuous Pralidoxime Infusion versus Intermittent Dosing: Application of High-Performance Liquid Chromatography Method on Serum of Organophosphate Poisoned Patients

Background: The effective therapeutic dose of pralidoxime methylsulphate for organophosphate (OP) poisoning is necessary to be clarified. This study was designed to comparatively assess the blood level of pralidoxime (BPL) and clinical outcomes in OP poisoned patients treated with intermittent dosing and patients treated with continuous infusion. Methods: This was a prospective, open labelled, ...

متن کامل

Composition and Synthesis of Lipids in Resting and Phagocytizing Leukocytes

The lipid content of rabbit polymorphonuclear leukocytes, obtained from peritoneal exudates, constituted 8.7 +/- 2.9 per cent of the dry weight of these cells; 60 per cent of all lipids were phospholipids, 20 per cent triglycerides, and the remainder cholesterol and cholesterol esters and a small amount of non-esterified fatty acids (2 to 4 per cent). The composition of the fatty acids in leuko...

متن کامل

Determination of Two Antiepileptic Drugs in Urine by Homogenous Liquid-Liquid Extraction Performed in A Narrow Tube Combined With Dispersive Liquid-liquid Microextraction Followed by Gas Chromatography-flame Ionization Detection

A simple and efficient homogenous liquid-liquid extraction method performed in a narrow tube combined with dispersive liquid-liquid microextraction method has been presented for the simultaneous determination of two antiepileptic drugs in urine followed by gas chromatography with flame ionization detection. In this method, a mixture of acetonitrile and urine sample (homogenous solution) is load...

متن کامل

Determination of Two Antiepileptic Drugs in Urine by Homogenous Liquid-Liquid Extraction Performed in A Narrow Tube Combined With Dispersive Liquid-liquid Microextraction Followed by Gas Chromatography-flame Ionization Detection

A simple and efficient homogenous liquid-liquid extraction method performed in a narrow tube combined with dispersive liquid-liquid microextraction method has been presented for the simultaneous determination of two antiepileptic drugs in urine followed by gas chromatography with flame ionization detection. In this method, a mixture of acetonitrile and urine sample (homogenous solution) is load...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:
  • Clinical chemistry

دوره 22 10  شماره 

صفحات  -

تاریخ انتشار 1976