Reality-Based Estimation of Needle and Soft-Tissue Interaction for Accurate Haptic Feedback in Prostate Brachytherapy Simulation
نویسندگان
چکیده
∗ This work was supported in part by National Science Foundation CAREER award IIS 0133471 and NSF ITR award 0312709. Mr. James Hing is a graduate student in the PRISM laboratory (e-mail: [email protected]). Dr. Ari D. Brooks is a General Surgeon specializing in Surgical Oncology at Drexel University College of Medicine (email: [email protected]). Dr. Jaydev P. Desai is the Director of the PRISM Laboratory, Drexel University, Philadelphia, PA 19104, USA (corresponding author, phone: 215-895-1738; fax: 215-895-1940; e-mail: [email protected]). a Corresponding author. Abstract – Prostate Brachytherapy is the implantation of radioactive seeds into the prostate as a treatment for prostate cancer. The success rate of the procedure is directly related to the physician’s level of experience. In addition, minor deviations in seed alignment caused by gland compression/retraction, gland edema (swelling) and needle deflections can create significant areas of over or under dosage to the gland and/or injury to surrounding nerves and organs, leading to increased morbidity. Therefore, reductions in brachytherapy complication rates will be dependent on improving the tools physicians use for training to improve the accuracy of needle guidance and deployment of ‘seeds’ within the prostate gland. Through our novel approach of using two C-ARM fluoroscopes, we propose a reality-based approach for estimating needle and soft tissue interaction for the purpose of eventually developing an accurate seed placement training simulator with haptic feedback for prostate brachytherapy. By recording implanted fiducial movement and needle-soft tissue interaction forces, we can: extract the local effective modulus during puncture events, quantify tissue deformation, obtain an approximate cutting force, and build a finite element model to provide accurate haptic feedback in the training simulator for needle insertion tasks.
منابع مشابه
3D Needle-Tissue Interaction Simulation for Prostate Brachytherapy
This paper presents a needle-tissue interaction model that is a 3D extension of a prior work based on the finite element method. The model is also adapted to accommodate arbitrary meshes so that the anatomy can effectively be meshed using third-party algorithms. Using this model a prostate brachytherapy simulator is designed to help medical residents acquire needle steering skills. This simulat...
متن کاملSoft Tissue Modeling Using ANFIS for Training Diagnosis of Breast Cancer in Haptic Simulator
Soft tissue modeling for the creation of a haptic simulator for training medical skills has been the focus of many attempts up to now. In soft tissue modeling the most important parameter considered is its being real-time, as well as its accuracy and sensitivity. In this paper, ANFIS approach is used to present a nonlinear model for soft tissue. The required data for training the neuro-fuzzy mo...
متن کاملSoftness Haptic Display Device for Human - Computer Interaction
In the field of virtual reality and teleoperation, haptic interaction between human operator and a computer or telerobot plays an increasingly important role in performing delicate tasks, such as robotic telesurgery, virtual reality based training systems for surgery, virtual reality based rehabilitation systems (Dario et al, 2003) (Taylor, Stoianovici, 2003) (Popescu, et al, 2000), etc. These ...
متن کاملRobot-Assisted Prostate Brachytherapy
In contemporary brachytherapy procedures, needle placement at the desired target is challenging due to a variety of reasons. A robot-assisted brachytherapy system can improve the needle placement and seed delivery resulting in enhanced patient care. In this paper we present a 16 DOF (degrees-of-freedom) robotic system (9DOF positioning module and 7 DOF surgery module) developed and fabricated f...
متن کاملModeling of Needle-Tissue Interaction Using Ultrasound-Based Motion Estimation
A needle-tissue interaction model is an essential part of every needle insertion simulator. In this paper, a new experimental method for the modeling of needle-tissue interaction is presented. The method consists of measuring needle and tissue displacements with ultrasound, measuring needle base forces, and using a deformation simulation model to identify the parameters of a needle-tissue inter...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
عنوان ژورنال:
دوره شماره
صفحات -
تاریخ انتشار 2005