Identification of independent risk factors for restenosis following bare-metal stent implantation: Role of bare-metal stents in the era of drug-eluting stents

نویسندگان

  • CHANG-BUM PARK
  • HOON-KI PARK
چکیده

In the era of drug-eluting stents (DESs), the ability of clinicians to predict which patients have a low risk of coronary restenosis following bare-metal stent (BMS) implantion is likely to be of benefit. The study population consisted of 2,711 patients who underwent BMS implantation in 3,770 lesions between 1995 and 2004. With clinical and 6 month follow-up angiographic data, we retrospectively sought to identify the independent risk predictors of restenosis, applied a previously proposed prediction model and assessed the characteristics of patients with a low likelihood of coronary restenosis within 6 months of BMS implantation. A 6-month follow-up coronary angiography was performed in 65.0% of the patients who had undergone the BMS implantation and the rate of restenosis was 26.6%. Using multivariate analysis, diabetes [odds ratio (OR), 1.294; 95% confidence interval (CI), 1.094-1.483; P=0.005], current smoking (OR, 1.294; 95% CI, 1.094-1.483; P=0.002), a reference vessel diameter of <3.25 mm (OR, 1.238; 95% CI, 1.021-1.501; P<0.001), a lesion length of >30 mm (OR, 1.645; 95% CI, 1.336-2.026; P<0.001), ostial lesion (OR, 1.858; 95% CI, 1.437-2.402; P<0.001), post-stenting minimal luminal diameter (OR, 0.576; 95% CI, 0.484-0.685; P<0.001) and bifurcation lesion (OR, 1.353; 95% CI, 1.070-1.711; P=0.012) were identified as significant independent predictors of restenosis. However, the accuracy of the prediction obtained with the current model, which used the clinical and angiographic variables correlated with the risk of restenosis, was poor. Various clinical and angiographic independent risk variables were revealed to be correlated with the risk of restenosis following BMS implantation in the present large dataset. Certain groups of patients with a relatively low risk of restenosis may be considered for BMS implantation as an alternative to DESs. However, the prediction models used at present are incomplete and further studies are required.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Long-term safety and efficacy of drug-eluting versus bare-metal stents in Sweden.

BACKGROUND The long-term safety and efficacy of drug-eluting coronary stents have been questioned. METHODS We evaluated 47,967 patients in Sweden who received a coronary stent and were entered into the Swedish Coronary Angiography and Angioplasty Registry between 2003 and 2006 and for whom complete follow-up data were available for 1 to 5 years (mean, 2.7). In the primary analysis, we compare...

متن کامل

Outcomes following coronary stenting in the era of bare-metal vs the era of drug-eluting stents.

CONTEXT Although drug-eluting stents reduce restenosis rates relative to bare-metal stents, concerns have been raised that drug-eluting stents may also be associated with an increased risk of stent thrombosis. Our study focused on the effect of stent type on population-based interventional outcomes. OBJECTIVE To compare outcomes of Medicare beneficiaries who underwent nonemergent coronary ste...

متن کامل

Primary Stenting of Totally Occluded Native Coronary Arteries II (PRISON II): a randomized comparison of bare metal stent implantation with sirolimus-eluting stent implantation for the treatment of total coronary occlusions.

BACKGROUND Sirolimus-eluting stents markedly reduce the risk of restenosis compared with bare metal stents. However, it is not known whether there are differences in effectiveness between bare metal and sirolimus-eluting stents in patients with total coronary occlusions. METHODS AND RESULTS In a prospective, randomized, single-blind, 2-center trial, we enrolled 200 patients with total coronar...

متن کامل

The stenting strategy of drug-eluting stents for coronary artery disease in patients on dialysis

BACKGROUND Reports regarding the relationship between the length and diameter of implanted drug-eluting stents and clinical and angiographic outcomes in dialysis patients are limited. AIM We investigated the efficiency of drug-eluting stents for coronary artery disease in patients on dialysis from the viewpoint of stent sizing. METHODS Sirolimus-eluting stents were implanted in 88 lesions a...

متن کامل

Drug-Eluting Stent Restenosis

OBJECTIVES We sought to determine if the angiographic pattern of in-stent restenosis in drug-eluting stents (DES) maintains its prognostic importance. BACKGROUND The pattern of restenosis in the bare-metal stent era had a significant impact on therapeutic outcomes. METHODS We identified a total of 250 consecutive restenotic lesions in 203 patients (66.4% sirolimuseluting stents and 33.6% paclit...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره 6  شماره 

صفحات  -