Permittivity Measurements of Biological Samples by an Open-ended Coaxial Line

نویسندگان

  • J. S. Bobowski
  • T. Johnson
چکیده

We previously reported on the complex permittivity and dc conductivity of waste-activated sludge. The measurements, spanning a frequency range of 3 MHz to 40 GHz, were made using an open-ended coaxial transmission line. Although this technique is well established in the literature, we found that it was necessary to combine methods from several papers to use the open-ended coaxial probe to reliably characterize biological samples having a high dc conductivity. Here, we provide a set of detailed and practical guidelines that can be used to determine the permittivity and conductivity of biological samples over a broad frequency range. Due to the electrode polarization effect, low frequency measurements of conducting samples require corrections to extract the intrinsic electrical properties. We describe one practical correction scheme and verify its reliability using a control sample.

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Measurement of Complex Permittivity of Large Concrete Samples with an Open-Ended Coaxial Line

A 70 mm-open-ended coaxial line probe was developed to perform measurements of the dielectric properties of large concrete samples. The complex permittivity was measured in the frequency range 50 MHz – 1.5 GHz during the hardening process of the concrete. As expected, strong dependence of water content was observed.

متن کامل

Open-ended coaxial-line permittivity measurements on pulverized materials

The open-ended, coaxial-line probe technique can be used to obtain estimates of the pennittivities of some solid dielectrics over broad ranges of frequency by measurements on powdered or pulverized samples, but certain limitations must be recognized. Such a probe was used with a network analyzer to estimate the permittivities of coal and limestone from reflection coefficients measured on pulver...

متن کامل

Nonlinear time series modelling and prediction using Gaussian RBF networks with enhanced clustering - Electronics Letters

‘Reflection of an open-ended coaxial line and application to nondestructive measuremet of materials’, IEEE Trans., 1981, Ihl30, (1). PP. 46-51 3 GRANT, J.P., CLARKE, R.N., SYMM, G.T., and SPYROU, N.M.: ‘A critical study of the open-ended coaxial line sensor technique for FR and microwave complex permittivity measurements’, J. Phys. E: Sri. Instrum., 1989,22, pp. 757-770 4 ARAI, M., BINNER. J.G....

متن کامل

Analysis of an Open-Ended Coaxial Probe with Lift-Off for Nondestructive Testing

~bstkzcthe open-ended coaxial probe with lift-off is studied the effects of air gap on dielectric measurements. Also, in using a full-wave inalysis, and an uncertainty analysis is presented. The field equations for the following terminations are worked out: (1) the sample extends to x in the positive axial direction, (2) the sample is backed by a well-characterized material, and (3) the sample ...

متن کامل

Electromagnetic Characterization of Volcanic Ash

An open-ended coaxial probe is designed for making permittivity measurements on volcanic ash. Reference liquids such as water and methanol are used for calibrating the probe, whose input admittance is related to the complex permittivity by Marcuvitz integral. The reflection coefficient of the probe in the presence of volcanic ash samples from Etna volcano, Italy, is measured from 1 to 15 GHz an...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:

دوره   شماره 

صفحات  -

تاریخ انتشار 2012