Simultaneous Determination of Norfloxacin and Tinidazole Binary Mixture by Difference Spectroscopy

نویسندگان

  • Noura H. Abou-Taleb
  • Dina T. El-Sherbiny
  • Dalia R. El-Wasseef
  • Mohamed A. Abu El-Enin
  • Saadia M. El-Ashry
چکیده

A simple and rapid difference spectroscopic method was developed for the simultaneous determination of binary mixture of norfloxacin (NF) and tinidazole (TZ) without prior separation. The proposed method depends upon measuring the absorbance of NF at 291.6 nm which is the zero crossing point on the difference spectra of TZ in 0.1 N NaOH vs. 0.1 N HCl. Similarly, the absorbance of TZ was measured at 344.4 nm which is the zero crossing point on the difference spectra of NF. Beer's law was obeyed in the concentration range of 2-20 and 5-50 μg/mL for NF and TZ, respectively. The lower limits of detection (LOD) of NF and TZ are 0.23 and 0.36 μg/mL, respectively, while the lower limits of quantification (LOQ) of NF and TZ were 0.70 and 1.08 μg/mL, respectively. The precision of the method was satisfactory; the maximum value of relative standard deviations did not exceed 1.5% (n=10). The accuracy, expressed as recovery is between 98.25 and 101.8% with relative error of 0.29 and 0.23 for NF and TZ, respectively. The proposed method was successfully applied for the determination of both drugs in bulk powder, laboratory prepared mixture and commercial dosage forms such as tablets without interference from the commonly encountered excipients and additives. The results obtained are in good agreement with those obtained by the reference methods.

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Least-squares support vector machine and its application in the simultaneous quantitative spectrophotometric determination of pharmaceutical ternary mixture

This paper proposes the least-squares support vector machine (LS-SVM) as an intelligent method applied on absorption spectra for the simultaneous determination of paracetamol (PCT), caffeine (CAF) and ibuprofen (IB) in Novafen. The signal to noise ratio (S/N) increased. Also, In the LS - SVM model, Kernel parameter (σ2) and capacity factor (C) were optimized. Excellent prediction was shown usin...

متن کامل

Development of normalized spectra manipulating spectrophotometric methods for simultaneous determination of Dimenhydrinate and Cinnarizine binary mixture.

Simultaneous determination of Dimenhydrinate (DIM) and Cinnarizine (CIN) binary mixture with simple procedures were applied. Three ratio manipulating spectrophotometric methods were proposed. Normalized spectrum was utilized as a divisor for simultaneous determination of both drugs with minimum manipulation steps. The proposed methods were simultaneous constant center (SCC), simultaneous deriva...

متن کامل

Effect of Tinidazole on Norfloxacin Disposition

Background: Concomitant oral administration of NFX with TNZ may affect NFX absorption and consequently its blood concentration and pharmacological effect. Objective: The present study was undertaken to investigate the effect of TNZ on the pharmacokinetics of NFX in healthy volunteers. Methods: This study was conducted as an open-label, randomized, two-way crossover experimental design. After an...

متن کامل

Effect of Tinidazole on Norfloxacin Disposition

Background: Concomitant oral administration of NFX with TNZ may affect NFX absorption and consequently its blood concentration and pharmacological effect. Objective: The present study was undertaken to investigate the effect of TNZ on the pharmacokinetics of NFX in healthy volunteers. Methods: This study was conducted as an open-label, randomized, two-way crossover experimental design. After an...

متن کامل

Removal of Brilliant Green and Crystal violet from Mono- and Bi-component Aqueous Solutions Using NaOH-modified Walnut Shell

In the present work, the simultaneous determination of Brilliant green (BG) and Crystal violet (CV) dyes with overlapped absorption spectra in binary mixture solution, was carreid out using the partial least squares (PLS) and direct ortogonal signal correction-partial least squares (DOSC-PLS) methods. The results obtained indicate that by applying DOSC on the calibration and prediction data for...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:

دوره 7  شماره 

صفحات  -

تاریخ انتشار 2011