Critical evaluation of a new flame emission analysis system, the "Klina flame".

نویسندگان

  • R J Schlesinger
  • R A Lesonsky
  • R Lottritz
چکیده

Recently there have been several advances in instrumental methods for the flame emission analysis of electrolytecations of clinical significance. Greater precision and increased ease of operation are among today’s clinical requirements. This study compares a new automated flame photometer, “Klina Flame” (Beckman Instruments) with a “Techtron-AA5” atomic absorption emission unit (Varian Instruments) and an “IL 143” flame system (Instrumentation Laboratory). Day.to.day variation between paired data over a three-month period showed comparable and explainable similarities and variations between the three instruments. Results of lithium determinations gave favorable comparison statistics. Longterm stability on all the systems were generally comparable. A comparison of manual vs. automatic modes of dilution with serum samples of various viscosities generally gave predictable variation for instruments of similar quality. The piston dilutor feature of the Klina system seems to prevent the variability seen at higher viscosities when the IL system is used, which has a peristaltic dilutor.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Maximum Power Point Tracker for Photovoltaic Systems Based on Moth-Flame Optimization Considering Partial Shading Conditions

The performance of photovoltaic (PV) systems is highly dependent on environmental conditions. Due to probable changes in environmental conditions, the real-time control of PV systems is essential for exploiting their maximum possible power. This paper proposes a new method to track the maximum power point of PV systems using the moth-flame optimization algorithm. In this method, the PV DC-DC co...

متن کامل

Evaluation of the total analytical error in the flame photometry method

Background and Objectives: For total analytical error, imprecision (SD) and bias, performance goals for laboratory tests have most often been developed. A total analytical error goal requires that the combination of errors from all sources (random and systematic errors) be within some acceptable limit. M...

متن کامل

Preparation of Flame Retardant Polystyrene via In-Situ Bulk Polymerization Method and Evaluation of its Flammability Properties

In this study, in-situ bulk polymerization was investigated for obtaining flame retardant polystyrene (PS). The halogenated and phosphoric compounds were used as flame retardant additives and Perkadox 30 was used as a synergist. The flammability of the PS was evaluated by thermogravimetric analyzer (TGA), limiting oxygen index (LOI) and UL-94 tests. The results show that polymerization process ...

متن کامل

Thermo-Elastic-Plastic Analysis of Plate Forming Process by Flame Bending Method

Flame bending process is one of the forming processes of steel plates. During this process, plate is formed with heating by gas torch flame followed by controlled cooling along specified paths. Considering simple tools used in the process, it is a popular and economical forming method. At present, this process is manually done on the basis of skilled technician’s &#10experience. Experimental an...

متن کامل

Thermo-Elastic-Plastic Analysis of Plate Forming Process by Flame Bending Method

Flame bending process is one of the forming processes of steel plates. During this process, plate is formed with heating by gas torch flame followed by controlled cooling along specified paths. Considering simple tools used in the process, it is a popular and economical forming method. At present, this process is manually done on the basis of skilled technician’s experience. Experimental and ...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Clinical chemistry

دوره 18 9  شماره 

صفحات  -

تاریخ انتشار 1972