Testing of models of flow-induced hemolysis in blood flow through hypodermic needles.

نویسندگان

  • Yangsheng Chen
  • Timothy L Kent
  • M Keith Sharp
چکیده

Hemolysis caused by flow in hypodermic needles interferes with a number of tests on blood samples drawn by venipuncture, including assays for metabolites, electrolytes, and enzymes, causes discomfort during dialysis sessions, and limits transfusion flow rates. To evaluate design modifications to address this problem, as well as hemolysis issues in other cardiovascular devices, computational fluid dynamics (CFD)-based prediction of hemolysis has potential for reducing the time and expense for testing of prototypes. In this project, three CFD-integrated blood damage models were applied to flow-induced hemolysis in 16-G needles and compared with experimental results, which demonstrated that a modified needle with chamfered entrance increased hemolysis, while a rounded entrance decreased hemolysis, compared with a standard needle with sharp entrance. After CFD simulation of the steady-state velocity field, the time histories of scalar stress along a grid of streamlines were calculated. A strain-based cell membrane failure model and two empirical power-law blood damage models were used to predict hemolysis on each streamline. Total hemolysis was calculated by weighting the predicted hemolysis along each streamline by the flow rate along each streamline. The results showed that only the strain-based blood damage model correctly predicted increased hemolysis in the beveled needle and decreased hemolysis in the rounded needle, while the power-law models predicted the opposite trends.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

A strain-based flow-induced hemolysis prediction model calibrated by in vitro erythrocyte deformation measurements.

Hemolysis is caused by fluid stresses in flows within hypodermic needles, blood pumps, artificial hearts, and other cardiovascular devices. Developers of cardiovascular devices may expend considerable time and effort in testing of prototypes, because there is currently insufficient understanding of how flow-induced cell damage occurs to accurately predict hemolysis. The objective of this projec...

متن کامل

MECHANISMS OF BLOOD FLOW INCREASE INDUCED BY ELECTRICAL STIMULATION

Previous studies have shown that electrical stimulation (ES) increases blood flow, but the exact mechanisms are not clear. The present study was designed to clarify some of the underlying mechanisms involved in this phenomenon. White adult rabbits Lt.-6 months old were used. Animals were anesthetized by sodium pentobarbital (40 mg/kg, IV) and skin blood flow in the thoracic back was recorde...

متن کامل

Increase in the calculated resistance of anatomically fixed stenosis in vitro in association with decrease in distal resistance.

The effects of changes in distal resistance on stenotic resistance were studied in vitro. Physiological saline was passed through the left carotid artery obtained from the dog, flexible rubber tubing, or through solid polyethylene tubing with a constant perfusion pressure or with a constant flow rate. Various stenotic resistances were established using a screw type constrictor and the distal re...

متن کامل

Determination of arterial blood flow by percutaneously introduced flow sensors in an external magnetic field. I. The method.

A method for determining the rate of blood flow in arteries without surgical intervention is described. It is shown that a probe capable of securing such information about flow in a blood vessel can be introduced into the vascular tree by means of a needle puncture in the skin made by a no. 18-guage hypodermic needle. A snugly-fitting guide wire is passed through the needle, which is then withd...

متن کامل

Study of Pulsatile Non-Newtonian Blood Flow Through Abdominal Aorta and Renal Arteries Incorporating Fluid- Structure Interaction

Background: The interaction between the blood and the vessel wall is of great clinical interest in studying cardiovascular diseases, the major causes of death in developed countries.Objective: To understand the effects of incorporating fluid-structure interaction into the simulation of blood flow through an anatomically realistic model of abdominal aorta and renal arteries reconstructed from CT...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Artificial organs

دوره 37 3  شماره 

صفحات  -

تاریخ انتشار 2013