Real-Time Tracking of Aortic Valve Landmarks Based on 2D-2D Fluoroscopic Image Registration
نویسندگان
چکیده
Transcatheter aortic valve implantation (TAVI) is routinely performed under 2D fluoroscopic guidance. The target position for placement of the stented aortic valve prosthesis is defined by aortic valve landmarks, e.g. coronary ostia. This paper presents a real-time tracking method of these landmarks in 2D fluoroscopic image sequences to improve the positioning of the implant during TAVI. The proposed tracking method is based on the Insight Toolkit (ITK) registration framework. Minimal user-interaction is required to define 2D landmarks in a reference image. The reference image is automatically detected to present all image features, when the aortic root is filled with a contrast agent. Preliminary results showed a good tracking of the landmarks even without the contrast agent in 14 fluoroscopic image sequences.
منابع مشابه
Automatic Aorta Segmentation and Valve Landmark Detection in C-Arm CT: Application to Aortic Valve Implantation
C-arm CT is an emerging imaging technique in transcatheter aortic valve implantation (TAVI) surgery. Automatic aorta segmentation and valve landmark detection in a C-arm CT volume has important applications in TAVI by providing valuable 3D measurements for surgery planning. Overlaying 3D segmentation onto 2D real time fluoroscopic images also provides critical visual guidance during the surgery...
متن کاملDense 3D face alignment from 2D video for real-time use
To enable real-time, person-independent 3D registration from 2D video, we developed a 3D cascade regression approach in which facial landmarks remain invariant across pose over a range of approximately 60 degrees. From a single 2D image of a person’s face, a dense 3D shape is registered in real time for each frame. The algorithm utilizes a fast cascade regression framework trained on high-resol...
متن کاملAnatomical image-based rigid registration between fluoroscopic X-ray and CT: methods comparison and experimental results
This paper describes a practical, whole system approach to rigid registration between preoperative CT and intraoperative X-rays obtained with a tracked C-arm and demonstrates its efficacy experimentally. Our approach is generic, targeted to orthopaedic surgery, and includes fluoroscopic X-ray calibration, image distortion correction, optical tracking, and 2D/3D image registration. For 2D/3D ima...
متن کاملRespiratory motion compensation by model-based catheter tracking during EP procedures
In many cases, radio-frequency catheter ablation of the pulmonary veins attached to the left atrium still involves fluoroscopic image guidance. Two-dimensional X-ray navigation may also take advantage of overlay images derived from static pre-operative 3D volumetric data to add anatomical details otherwise not visible under X-ray. Unfortunately, respiratory motion may impair the utility of stat...
متن کاملSpatio-temporal (2D+T) non-rigid registration of real-time 3D echocardiography and cardiovascular MR image sequences.
In this paper we describe a method to non-rigidly co-register a 2D slice sequence from real-time 3D echocardiography with a 2D cardiovascular MR image sequence. This is challenging because the imaging modalities have different spatial and temporal resolution. Non-rigid registration is required for accurate alignment due to imprecision of cardiac gating and natural motion variations between card...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
عنوان ژورنال:
دوره شماره
صفحات -
تاریخ انتشار 2010