Effects of condensate in the exhalation limb of neonatal circuits on airway pressure during bubble CPAP.
نویسندگان
چکیده
BACKGROUND Bubble CPAP is frequently used in spontaneously breathing infants with lung disease. Often bubble CPAP systems lack pressure alarms and pressure-release valves. We observed a large volume of condensate in the exhalation limb of a patient circuit and conducted a series of experiments to test the hypothesis that accumulated condensate could affect delivered pressures. METHODS An anatomically accurate nasal airway model of a preterm infant was attached to a spontaneously breathing lung model. A bubble CPAP system was attached to the nasal airway with bi-nasal short prongs, and the rate of fluid condensation was measured. Next, tracheal pressures were monitored digitally to detect changes in airway pressure related to condensate accumulation. Measurements were obtained with volumes of 0, 5, 10, 15, and 20 mL of water in the exhalation limb, at flows of 4, 6, 8, and 10 L/min. Measurements with 20 mL in the exhalation limb were recorded with and without a pressure-relief valve in the circuit. RESULTS The rate of condensate accumulation was 3.8 mL/h. At volumes of ≥ 10 mL, noticeable alterations in the airway pressure waveforms and significant increases in mean tracheal pressure were observed. The pressure-relief valve effectively attenuated peak tracheal pressure, but only decreased mean pressure by 0.5-1.5 cm H2O. CONCLUSIONS Condensate in the exhalation limb of the patient circuit during bubble CPAP can significantly increase pressure delivered to the patient. The back and forth movement of this fluid causes oscillations in airway pressure that are much greater than the oscillations created by gas bubbling out the exhalation tube into the water bath. We recommend continuously monitoring pressure at the nasal airway interface, placing an adjustable pressure-relief valve in the circuit, set to 5 cm H2O above the desired mean pressure, and emptying fluid from the exhalation limb every 2-3 hours.
منابع مشابه
Effect of Bubble and Ventilator-derived Continuous Positive Airway Pressure on the Management of Respiratory Distress Syndrome in Premature Neonates
Background: In this study, we aimed to compare ventilator-derived and bubble continuous positive airway pressure (CPAP) in neonates with respiratory distress syndrome admitted to Neonatal Intensive Care Unit of Vali-e-Asr Hospital, Birjand, Iran, in 2014. Methods: This cohort study was conducted among 68 patients assigned into two groups. The neonates in group A (32 infants) were treated with b...
متن کاملBubble CPAP: not all bubbling is good bubbling.
Since its introduction over 30 years ago,1 bubble CPAP has become an important part of the management of neonatal respiratory distress syndrome. Similar to “ventilatorderived” or “machine-derived” CPAP devices, bubble CPAP devices apply pressure to the neonatal respiratory system via nasal prongs placed into the infant’s nostrils, forming a tight seal to minimize leak. On the other hand, bubble...
متن کاملComparison of the Therapeutic Effects of Bubble CPAP and Ventilator CPAP on Respiratory Distress Syndrome in Premature Neonates
Background: Respiratory distress syndrome is one of the main complications associated with low birth weight, and a main cause of mortality in premature neonates. The present study aimed to compare the efficacy of ventilator continuous positive airway pressure (CPAP) and bubble CPAP in the treatment of respiratory distress syndrome (RDS) in premature neonates. Methods: This randomized controlled...
متن کاملThe Effect of Body Position on Pain Due to Nasal Continuous Positive Airway Pressure (CPAP) in Premature Neonates: A Cross-Over Clinical Trial Study
Background The most common cause of admission to neonatal intensive care units (NICU) is respiratory distress syndrome. One of the respiratory assistance methods is using nasal continuous positive airway pressure (CPAP). Regarding the importance of pain control which is one of the major priorities in neonatal nursing care, this study aimed to evaluate the effect of body position on pain due to ...
متن کاملThe Effect of Non-nutritive Sucking on Transcutaneous Oxygen Saturation in Neonates under the Nasal Continuous Positive Airway Pressure (CPAP)
BackgroundSeveral beneficial effects of non-nutritive sucking in infants, including the physiological stability, relaxation, better transition from tube feeding to oral feeding have been reported. But its effect on oxygen saturation in neonates under the Nasal Continuous Positive Airway Pressure (NCPAPو (is not so clear. This study aimed to investigate the effects of non-nutritive sucking on tr...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
عنوان ژورنال:
- Respiratory care
دوره 58 11 شماره
صفحات -
تاریخ انتشار 2013