Analysis of DNA in Phosphate Buffered Saline Using Kinetic Capillary Electrophoresis.
نویسندگان
چکیده
Kinetic capillary electrophoresis (KCE) methods are useful in the study of kinetics and equilibrium properties of interactions between DNA and its binding partners (ligands). KCE experiments are typically performed in a narrow set of "conventional" low-conductivity run buffers while DNA-ligand interactions in biological systems occur in physiological fluids, characterized by high ionic strengths. The nature and ionic strength of the buffer, in which DNA-ligand interaction occurs, can significantly influence the binding. Therefore, KCE experiments meant to study such interactions would greatly benefit if they could be performed in physiological buffers, such as phosphate buffered saline (PBS). No previous KCE studies of DNA used PBS as the run buffer. Here, we test the feasibility of using PBS as a KCE run buffer for analysis of DNA and show that its usage under standard KCE conditions renders DNA undetectable. We uncover the causes of this previously unreported detrimental effect and come up with a modification of KCE which allows one to overcome it. We apply the modified KCE method to an experimental model of a platelet-derived growth factor (PDGF) protein and its DNA aptamer, which was selected in PBS, and show that the results obtained in PBS run buffer are much closer to previously reported values than those which were obtained with a conventional low-conductivity capillary electrophoresis (CE) buffer.
منابع مشابه
Chiral Separation of Basic and Zwitterionic Drugs by Highly Sulfated Cyclodextrins Using Short-End Injection Capillary Electrophoresis Highly Sulfated Cyclodextrins Using Short-End Injection Capillary Electrophoresis
Due to high resolution power of sulfated cyclodextrins (HS-CDs), utilization of these selectors for chiral resolution of 7 basic and 2 zwitterionic drugs have been examined. Experiments were performed on a HP3DCE instrument equipped with an on-column diode array UV absorbance detector. Fused silica capillaries with an inner diameter of 50 ?m, an outer diameter of 365 ?m, and a total length of 4...
متن کاملDual examinations for identification of urine as being of human origin and for DNA-typing from small stains of human urine.
Concurrent methods for identification of urine as being of human origin, and for DNA-typing from small stains of human urine were examined. A urine stain was extracted with phosphate-buffered saline (PBS), and the extract was filtered using a Centricon-100 device. The filtrate was subjected to electrospray ionization liquid chromatography-mass spectrometry (ESI-LC-MS) for identification of huma...
متن کاملChiral Separation of Basic and Zwitterionic Drugs by Highly Sulfated Cyclodextrins Using Short-End Injection Capillary Electrophoresis Highly Sulfated Cyclodextrins Using Short-End Injection Capillary Electrophoresis
Due to high resolution power of sulfated cyclodextrins (HS-CDs), utilization of these selectors for chiral resolution of 7 basic and 2 zwitterionic drugs have been examined. Experiments were performed on a HP3DCE instrument equipped with an on-column diode array UV absorbance detector. Fused silica capillaries with an inner diameter of 50 ?m, an outer diameter of 365 ?m, and a total length of 4...
متن کاملIntroducing a New and Simple Protocol for Capillary Electrophoresis of Cell Free Fetal Double Stranded DNA
Isolation of cell free fetal DNA (cffDNA) from maternal serum usually leads to very low concentrations of DNA impeding further resolving through conventional methods of electrophoresis. Although several protocols have been described for capillary electrophoresis (CE) of double stranded DNA, they usually need using special polymers or coated capillaries which degrade over time. Herein, we propos...
متن کاملA stability indicating capillary electrophoresis method for analysis of buserelin
A simple and rapid stability indicating method based on capillary zone electrophoresis has been developed and validated for the analysis of buserelin (BUS). The best separations were achieved by using a bare fused silica capillary (75 m i.d.; 65.5 cm total, 57.0 cm effective length), phosphate buffer (pH = 3.00; 26.4 mM), at 35 °C. The sample was hydrodynamically injected at 50 mbar for 5 seco...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
عنوان ژورنال:
- Analytical chemistry
دوره 88 14 شماره
صفحات -
تاریخ انتشار 2016