T2* mapping with background gradient correction using different excitation pulse shapes.

نویسندگان

  • N M Hirsch
  • C Preibisch
چکیده

SUMMARY Background gradients induced by magnetic susceptibility variations near air-filled cavities in the brain cause signal-intensity loss in gradient-echo images and shorten T2* considerably. With a correction method in which the exponential decay is restored with section-profile-dependent correction factors, parts of the signal intensity can be recovered. While uncorrected T2* values drop by 20% at a gradient strength of 75 μT/m, with correction and exponential excitation pulses, this boundary is pushed to 220 μT/m.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Background Gradient Correction using Excitation Pulse Profile for Fat and T2* Quantification in 2D Multi-Slice Liver Imaging

Purpose : The objective of this study was to develop background gradient correction method using excitation pulse profile compensation for accurate fat and T2* quantification in the liver. Materials and Methods: In liver imaging using gradient echo, signal decay induced by linear background gradient is weighted by an excitation pulse profile and therefore hinders accurate quantification of T2* ...

متن کامل

Factors influencing flip angle mapping in MRI: RF pulse shape, slice-select gradients, off-resonance excitation, and B0 inhomogeneities.

To understand the various effects that influence actual flip angles, and correct for these effects, it is important to precisely quantify the MRI parameters (such as T1, T2, and perfusion). In this paper actual flip angle maps are calculated using a conventional gradient-echo (GRE) sequence with different radiofrequency (RF) pulse shapes (Gaussian, sinc, and truncated-sinc), slice-selection gra...

متن کامل

B1 Mapping with whole brain coverage in less than one minute

Introduction There is great demand for fast B1 mapping techniques, e.g. for correction of magnetization transfer ratio maps [1] or of quantitative T1 maps [2]. Several methods have been proposed, such as the acquisition of a spin echo and a stimulated echo (STE) [3], the performance of two acquisitions with different excitation angles [4], or the interleaved acquisition of two FLASH images with...

متن کامل

Reconstruction Strategies for MRI with Simultaneous Excitation and Acquisition

Introduction Imaging of samples with very short T2 requires data acquisition to start immediately after excitation. In the radial FID method [1] this is accomplished by excitation and acquisition during a permanently applied gradient. However, for high bandwidths the FID approach must use very short RF pulses, limiting the possible flip angle according to the given maximum B1 amplitude. On the ...

متن کامل

R2/R2* estimation errors in combined gradient- and spin-echo EPI sequences due to slice-profile differences between RF pulses

Introduction There is increased interest in a combined acquisition of gradient-echo (GE) and spin-echo (SE) signals for applications in DSC-PWI and fMRI. One of the main reasons is the different sensitivity of GEs and SEs to different compartments of the underlying microvasculature. While GEs are sensitive to both static and dynamic dephasing of spins, SEs are sensitive to dynamic spin dephasin...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • AJNR. American journal of neuroradiology

دوره 34 6  شماره 

صفحات  -

تاریخ انتشار 2013