Recording of EEG during functional MRI experiments: Artefacts

نویسندگان

  • G. Polizzi
  • P. Allen
  • L. Lemieux
  • D. Fish
چکیده

We examined seizure outcome Cfree ,from seizures however minor vs. continuing seizures however infrequent) 5 years post-TLES for mesial temporal sclerosis in 82 consecutive patients, aged 8-43 years, who underwent pharmacologically activated sphenoidal EEG pre-operatively (12 with extracranial ictal monitoring (VT), 70 without). Fifty-six had suffered an early-childhood complicated convulsion (ECC+); 56 had strictly unilateral sphenoidal spikes (SphU). The 70 non-monitored patients were divided according to the presence/absence of ECCf and of SphU. Those seizure free were: 78%. ECCf, SphU (N = 37) + 14% Engel other 1-t 11; 60%, ECC+, not SphU (N = 10) + 30% Engel other I + 11; 47%, not ECC+, SphU (N = 15); 25%, not ECC+, not SphU (N = 8). VT patients had no better outcome in any group. Therefore, excellent outcome is achieved for most with both ECC+ and SphU making routine VT unnecessary. Videotelemetry may be indicated (often intracranially) for all without ECC+, and for some (usually only extracranially) with ECC+ but not SphU.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Synchronization facilitates removal of MRI artefacts from concurrent EEG recordings and increases usable bandwidth.

Investigating human brain function non-invasively by simultaneous EEG and fMRI measurements is gaining in popularity as more and better solutions to the inherent technical challenges emerge. We demonstrate the use of a commercially available frequency divider and phase-locking device for the purpose of synchronizing an MRI acquisition with a simultaneous recording of the EEG. Synchronization hu...

متن کامل

Effects of simultaneous EEG recording on MRI data quality at 1.5, 3 and 7 tesla.

Although the focus of attention on data degradation during simultaneous MRI/EEG recording has to date largely been upon EEG artefacts, the presence of the conducting wires and electrodes of the EEG recording system also causes some degradation of MRI data quality. This may result from magnetic susceptibility effects which lead to signal drop-out and image distortion, as well as the perturbation...

متن کامل

A comparative study of different artefact removal algorithms for EEG signals acquired during functional MRI

In electroencephalographic (EEG) measurements performed during functional Magnetic Resonance Imaging (fMRI), imaging and cardiac artefacts strongly contaminate the EEG signal. Several algorithms have been proposed to suppress these artefacts and most of them have shown important improvements with respect to uncorrected signals. However, the relative performances of these algorithms have not bee...

متن کامل

Reducing the Gradient Artefact in Simultaneous EEG-fMRI by altering the Subject’s Axial Position

Large artefacts which compromise EEG data quality are generated when electroencephalography (EEG) and functional magnetic resonance imaging (fMRI) are carried out concurrently. The gradient artefact produced by the time-varying magnetic field gradients is the largest of these artefacts. Although average artefact correction (AAS) and related techniques can remove the majority of this artefact, t...

متن کامل

Reducing the gradient artefact in simultaneous EEG-fMRI by adjusting the subject's axial position

Large artefacts that compromise EEG data quality are generated when electroencephalography (EEG) and functional magnetic resonance imaging (fMRI) are carried out concurrently. The gradient artefact produced by the time-varying magnetic field gradients is the largest of these artefacts. Although average artefact correction (AAS) and related techniques can remove the majority of this artefact, th...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Seizure

دوره 7  شماره 

صفحات  -

تاریخ انتشار 1998