Fast low-specific absorption rate B0 -mapping along projections at high field using two-dimensional radiofrequency pulses.
نویسندگان
چکیده
PURPOSE At 7 Tesla (T), conventional static field (B0 ) projection mapping techniques, e.g., FASTMAP, FASTESTMAP, lead to elevated specific absorption rates (SAR), requiring longer total acquisition times (TA). In this work, the series of adiabatic pulses needed for slab selection in FASTMAP is replaced by a single two-dimensional radiofrequency (2D-RF) pulse to minimize TA while ensuring equal shimming performance. METHODS Spiral gradients and 2D-RF pulses were designed to excite thin slabs in the small tip angle regime. The corresponding selection profile was characterized in phantoms and in vivo. After optimization of the shimming protocol, the spectral linewidths obtained after 2D localized shimming were compared with conventional techniques and published values from (Emir et al NMR Biomed 2012;25:152-160) in six different brain regions. RESULTS Results on healthy volunteers show no significant difference (P > 0.5) between the spectroscopic linewidths obtained with the adiabatic (TA = 4 min) and the new low-SAR and time-efficient FASTMAP sequence (TA = 42 s). The SAR can be reduced by three orders of magnitude and TA accelerated six times without impact on the shimming performances or quality of the resulting spectra. CONCLUSION Multidimensional pulses can be used to minimize the RF energy and time spent for automated shimming using projection mapping at high field.
منابع مشابه
SA2RAGE: a new sequence for fast B1+ -mapping.
At high magnetic field strengths (≥ 3T), the radiofrequency wavelength used in MRI is of the same order of magnitude of (or smaller than) the typical sample size, making transmit magnetic field (B1+) inhomogeneities more prominent. Methods such as radiofrequency-shimming and transmit SENSE have been proposed to mitigate these undesirable effects. A prerequisite for such approaches is an accurat...
متن کاملA simple low-SAR technique for chemical-shift selection with high-field spin-echo imaging.
We have discovered a simple and highly robust method for removal of chemical shift artifact in spin-echo MR images, which simultaneously decreases the radiofrequency power deposition (specific absorption rate). The method is demonstrated in spin-echo echo-planar imaging brain images acquired at 7 T, with complete suppression of scalp fat signal. When excitation and refocusing pulses are suffici...
متن کاملPerformance of two spin-echo sequences for quantitative structure analysis of trabecular bone
Introduction: The susceptibility difference between bone and bone marrow promotes the use of spin echo-based sequences for high resolution magnetic resonance imaging (μMRI) of trabecular bone (TB) [1], particularly for B0>1.5T. At ultra high field strengths, specific absorption rate (SAR) limits for patient safety are breached by the fast large-angle spin-echo (FLASE) pulse sequence. Fast spin ...
متن کاملRegularized Estimation of Main and RF Field Inhomogeneity and Longitudinal Relaxation Rate in Magnetic Resonance Imaging
Regularized Estimation of Main and RF Field Inhomogeneity and Longitudinal Relaxation Rate in Magnetic Resonance Imaging by Amanda K. Funai Chair: Jeffrey A. Fessler In designing pulses and algorithms for magnetic resonance imaging, several simplifications to the Bloch equation are used. However, as magnetic resonance (MR) imaging requires higher temporal resolution and faster pulses are used, ...
متن کاملA simple and analytical way to correct for ΔB0 inhomogeneity in the evaluation of B1 maps relying on flip angle measurements and non-selective square pulses
Introduction: Efficient mitigation of the radiofrequency (RF) inhomogeneity at high field using coil arrays relies on the accurate knowledge of the individual B1 maps. Based on these maps, algorithms using diverse k-space trajectories can return RF waveforms which homogenize the flip angle (FA). The algorithms initially aimed at counteracting the B1 inhomogeneity only [1, 2], until the spatial ...